Carrier Air Handler: Forced operation using the AUTO/COOL button
Forced operation using the AUTO/COOL button on a Carrier air handler: Pressing the AUTO/COOL button starts a forced sequence. Forced cooling runs the compressor and outdoor fan with the indoor fan on breeze speed, then after 30 minutes the unit changes to auto mode at a preset 76°F (24°C). Forced auto runs like normal auto mode at a preset 76°F (24°C). Forced operation ends when the unit is switched off or when a remote signal changes the running mode.
Applies to: D5FSAA
How to fix forced operation using the auto/cool button: step by step
- Press the AUTO/COOL button once to start forced cooling.
- Wait 30 minutes; the unit moves to auto mode at 76°F (24°C).
- To use forced auto, select it with the button sequence and leave the preset at 76°F (24°C).
- To end forced operation, switch the unit off or send a remote command that changes the mode.
If the unit shows an error code, look it up: Carrier Air Handler codes
More button combinations tips for air handler
Source: Carrier D5FSAA product data, p. 4. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.