Button combinations: Air Handler tips

Updated · by Aurora Star Tech Inc.

Short, practical technician tips on button combinations for air handler. Check each one against the manual for your exact model before acting.

Black button forced modes (scenario 2 only)

Carrier · D5FUAA indoor unit, scenario 2

On scenario 2 units, the black button on the indoor board steps through forced modes. Long press under forced cooling forces defrost.

  1. Press the black button once to enter forced automatic mode.
  2. Press again to enter forced cooling mode (display shows FC).
  3. Press again to shut down.
  4. In forced cooling, long press the black button for 5 s to enter forced defrost.

Force defrost from outdoor unit SW4 button

Carrier · Outdoor unit paired with D5FUAA air handler

Holding the SW4 button on the outdoor unit starts a forced defrost.

  1. Press and hold the SW4 button on the outdoor unit for 10 seconds.

Forced operation using the AUTO/COOL button

Carrier · D5FSAA

Pressing the AUTO/COOL button starts a forced sequence. Forced cooling runs the compressor and outdoor fan with the indoor fan on breeze speed, then after 30 minutes the unit changes to auto mode at a preset 76°F (24°C). Forced auto runs like normal auto mode at a preset 76°F (24°C). Forced operation ends when the unit is switched off or when a remote signal changes the running mode.

  1. Press the AUTO/COOL button once to start forced cooling.
  2. Wait 30 minutes; the unit moves to auto mode at 76°F (24°C).
  3. To use forced auto, select it with the button sequence and leave the preset at 76°F (24°C).
  4. To end forced operation, switch the unit off or send a remote command that changes the mode.

Lock or unlock the wireless remote

Carrier · Wireless remote RG10F8(2)/BGEFU1

Holding TURBO and the C/F button together locks or unlocks the remote so buttons are not pressed by accident.

  1. Press and hold TURBO and the C/F button together for five seconds.
  2. Repeat to unlock. The LOCK display shows when the remote is locked.

Switch remote display between °F and °C

Carrier · Wireless remote RG10F8(2)/BGEFU1

Changes the temperature units shown on the remote.

  1. Press the TEMP increase and TEMP decrease buttons together and hold for about 3 seconds.
  2. Repeat to switch back.
  3. The default display is °F.

Switch the remote between °C and °F

Carrier · Wireless remote

The default display is °F. Pressing the two temperature set point buttons together switches the display units.

  1. Press and hold the + and - temperature set point buttons together for about 3 seconds.
  2. Repeat to switch back between °F and °C.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.