Updated · by Aurora Star Tech Inc.

Daikin DC6VS*481 error codes and diagnostic codes (also listed as DC6VS***1*A*). The DC6VS*481 is a Daikin air conditioner in the Daikin FIT DC6VS/DC9VSA series.

Homeowner with a air conditioner problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Daikin DC6VS*481 error codes list

CodeMeaningSeverity
14Repeated high pressure faults (minor)Medium
16Repeated low pressure faults (minor)Medium
33Outdoor control board overheating (minor)Medium
52Repeated compressor faults (minor)Medium
53Repeated outdoor fan / board faults (minor)Medium
54Repeated low discharge superheat faults (minor)Medium
55Repeated high discharge temperature faults (minor)Medium
57Sweating on the board cooling loopMedium
E11System start-up test not doneLow
E12Control board memory errorHigh
E13Repeated high pressure faults (critical)High
E15Repeated low pressure faults (critical)High
E17Repeated compressor faults (critical)High
E18Control board may need replacing (outdoor fan drive)High
E19Repeated outdoor fan / board faults (critical)High
E20Outdoor EEV faultHigh
E21Repeated low discharge superheat faultsHigh
E22Repeated high discharge temperature faultsHigh
E23Discharge temperature sensor out of rangeMedium
E24High pressure switch openHigh
E25Outdoor air temperature sensor open or shortedMedium
E26Pressure sensor not respondingMedium
E27Outdoor coil defrost sensor out of rangeMedium
E28Outdoor coil temperature sensor out of rangeMedium
E29Liquid temperature sensor out of rangeMedium
E30Control board may need replacingHigh
E32Outdoor control board overheating (critical)High
E34High current detectedHigh
E35High current, possible short circuitCritical
E36Abnormal start-upHigh
E37Control board may need replacing (fan motor link)High
E38Compressor voltage problemHigh
E39Control board may need replacing (thermistor input)High
E40Compressor setup does not match the unitHigh
E41Low refrigerantHigh
E42Low supply voltageHigh
E43High supply voltageHigh
E44Outdoor temperature out of operating rangeLow
E47System verification test blocked by indoor heatLow
E49Charging mode blocked by indoor heatLow
E50Voltage problem on the control boardHigh
E51Communication problem seen by the outdoor boardHigh
E56Suction temperature sensor out of rangeMedium
E58Compressor overload (OL) sensor openHigh
Eb0Indoor airflow near zeroHigh
Eb9Indoor airflow below what is neededMedium
Ed0No shared data on the controlHigh
Ed1Bad shared or network dataHigh
Ed2Airflow needed is more than the indoor unit can giveMedium
Ed3Shared data does not match the hardwareMedium
Ed4Memory card data rejectedMedium
Green Rx LED 1 steady flashNetwork: no network foundMedium
Green Rx LED offNetwork: no power or no communicationMedium
Green Rx LED on solidNetwork: terminal 1 / 2 miswiredMedium
Red comm LED 1 flashNetwork: communications failureMedium
Red comm LED 2 flashesNetwork: out-of-box resetLow

Troubleshooting the DC6VS*481

All Daikin Air Conditioner error codes →

Homeowner help: AC Running But Not Cooling: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.