Navien Error Code A873: Inverter trip alarm: Stator overheat (5 min) (AC)
Navien error code A873 on a air conditioner means: Inverter trip alarm: Stator overheat (5 min). It is also called Navien diagnostic code A873.
Homeowner? What Navien code A873 means for you
Check, then call Your air conditioner is reporting: Inverter trip alarm: Stator overheat (5 min). This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
- If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Navien error code A873 mean?
Inverter alarm (auto reset). Four occurrences give error E823 (display shows 873).
Applies to: NAE28V3622A1, NAE28V6022A1
Navien models that use code A873
Other Navien AC codes
All Navien Air Conditioner error codes →
Navien code A873: homeowner questions
What does Navien code A873 mean?
Inverter trip alarm: Stator overheat (5 min). Inverter alarm (auto reset). Four occurrences give error E823 (display shows 873).
Is it safe to keep using my air conditioner with code A873?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Navien code A873 myself?
You can try one reset (power off for 30 seconds, then on). If Navien code A873 comes back, the cause is still there and a licensed technician should check it.
Who can fix Navien code A873 near me?
Aurora Star Tech Inc. repairs Navien air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check
Troubleshooting guides
- Bubbles in sight glass / temperature drop across liquid line drier All brands · Air Conditioner
- Coil iced, airflow blocked, poor cooling, high box temp All brands · Air Conditioner
- Continuous run, no cooling, condenser cooler than normal All brands · Air Conditioner
- Evaporator freezing All brands · Air Conditioner
- Freezing in cold weather All brands · Air Conditioner
- General service-call symptom list All brands · Air Conditioner
- Hard starting / stalls on restart All brands · Air Conditioner
- Humid indoor air All brands · Air Conditioner
Source: Navien NAE I&O manual (07/2026), 7.1 Alarm table and 7.2, p.40. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.