Daikin Error Code E32: Outdoor control board overheating (critical) (AC)

Updated · by Aurora Star Tech Inc.

Daikin error code E32 on a air conditioner means: Outdoor control board overheating (critical). It is also called Daikin diagnostic code E32.

High severityAir ConditionerAlso Heat PumpDaikin FIT DC6VS/DC9VSA

Homeowner? What Daikin code E32 means for you

Call a technician Your air conditioner is reporting: Outdoor control board overheating (critical). The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code E32 mean?

Thermostat shows 32, outdoor board display shows E32. The outdoor control board keeps running too hot.

Applies to: DC6VS***1*A*, DC9VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)

Common causes of Daikin code E32

  • Outdoor temperature too high
  • Stop valve not fully open
  • Board cooling bracket screws missing or loose (3.5-5.0 ton FIT and 3.0-4.0 ton Enhanced Capacity/High Efficiency FIT only)

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Daikin models that use code E32

DC6VS*181DC6VS*241DC6VS*301DC6VS*361DC6VS*421DC6VS*481DC6VS*601DC9VSA2410DC9VSA3610DC9VSA4810

Other Daikin AC codes

CodeMeaning
E25Outdoor air temperature sensor open or shorted
E26Pressure sensor not responding
E27Outdoor coil defrost sensor out of range
E28Outdoor coil temperature sensor out of range
E29Liquid temperature sensor out of range
E30Control board may need replacing
E34High current detected
E35High current, possible short circuit
E36Abnormal start-up
E37Control board may need replacing (fan motor link)
E38Compressor voltage problem
E39Control board may need replacing (thermistor input)

All Daikin Air Conditioner error codes →

Daikin code E32: homeowner questions

What does Daikin code E32 mean?

Outdoor control board overheating (critical). Thermostat shows 32, outdoor board display shows E32. The outdoor control board keeps running too hot.

Is it safe to keep using my air conditioner with code E32?

It depends on the cause. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Daikin code E32 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code E32 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code E32 near me?

Aurora Star Tech Inc. repairs Daikin air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.44 (printed page). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977