Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin Error Code E18: Control board may need replacing (outdoor fan drive) (AC)

Updated · by Aurora Star Tech Inc.

Daikin error code E18 on a air conditioner means: Control board may need replacing (outdoor fan drive). It is also called Daikin diagnostic code E18.

High severityAir ConditionerAlso Heat PumpDaikin FIT DC6VS/DC9VSA

Homeowner? What Daikin code E18 means for you

Call a technician Your air conditioner is reporting: Control board may need replacing (outdoor fan drive). The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code E18 mean?

Thermostat shows 18, outdoor board display shows E18. The control flags itself as possibly bad. The manual points at the outdoor fan motor connection first.

Applies to: DC6VS***1*A*, DC9VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)

Common causes of Daikin code E18

  • Outdoor fan motor not plugged in right
  • Bad control board
  • Electrical noise
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Daikin models that use code E18

DC6VS*181DC6VS*241DC6VS*301DC6VS*361DC6VS*421DC6VS*481DC6VS*601DC9VSA2410DC9VSA3610DC9VSA4810

Other Daikin AC codes

CodeMeaning
CoreSense TRIP+ALERT flashingCoreSense: TRIP and ALERT flashing together
E11System start-up test not done
E12Control board memory error
E13Repeated high pressure faults (critical)
E15Repeated low pressure faults (critical)
E17Repeated compressor faults (critical)
E19Repeated outdoor fan / board faults (critical)
E20Outdoor EEV fault
E21Repeated low discharge superheat faults
E22Repeated high discharge temperature faults
E23Discharge temperature sensor out of range
E24High pressure switch open

All Daikin Air Conditioner error codes →

Daikin code E18: homeowner questions

What does Daikin code E18 mean?

Control board may need replacing (outdoor fan drive). Thermostat shows 18, outdoor board display shows E18. The control flags itself as possibly bad. The manual points at the outdoor fan motor connection first.

Is it safe to keep using my air conditioner with code E18?

It depends on the cause. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Daikin code E18 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code E18 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code E18 near me?

Aurora Star Tech Inc. repairs Daikin air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.43 (printed page). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977