Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin Error Code E11: System start-up test not done (AC)

Updated · by Aurora Star Tech Inc.

Daikin error code E11 on a air conditioner means: System start-up test not done. It is also called Daikin diagnostic code E11.

Low severityAir ConditionerAlso Heat PumpDaikin FIT DC6VS/DC9VSA

Homeowner? What Daikin code E11 means for you

Usually minor Your air conditioner is reporting: System start-up test not done. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Daikin error code E11 mean?

Thermostat message only. The system start-up test has not been run, or is running now. The code clears when the test finishes.

Applies to: DC6VS***1*A*, DC9VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)

Common causes of Daikin code E11

  • System start-up test not run or not finished
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Daikin models that use code E11

DC6VS*181DC6VS*241DC6VS*301DC6VS*361DC6VS*421DC6VS*481DC6VS*601DC9VSA2410DC9VSA3610DC9VSA4810

Other Daikin AC codes

CodeMeaning
CoreSense 4CoreSense: 4 flashes, locked rotor (yellow alert / red lock)
CoreSense 5CoreSense: 5 flashes, moderate run trip (yellow alert / red lock)
CoreSense 9CoreSense: red 9 flashes, PROT terminal over current
CoreSense solid redCoreSense: solid red TRIP
CoreSense solid yellowCoreSense: solid yellow RUN
CoreSense TRIP+ALERT flashingCoreSense: TRIP and ALERT flashing together
E12Control board memory error
E13Repeated high pressure faults (critical)
E15Repeated low pressure faults (critical)
E17Repeated compressor faults (critical)
E18Control board may need replacing (outdoor fan drive)
E19Repeated outdoor fan / board faults (critical)

All Daikin Air Conditioner error codes →

Daikin code E11: homeowner questions

What does Daikin code E11 mean?

System start-up test not done. Thermostat message only. The system start-up test has not been run, or is running now. The code clears when the test finishes.

Is it safe to keep using my air conditioner with code E11?

Usually yes. Code E11 is normally minor, but if it keeps coming back have it checked.

Can I reset Daikin code E11 myself?

You can try one reset (power off for 30 seconds, then on). If Daikin code E11 comes back, the cause is still there and a licensed technician should check it.

Who can fix Daikin code E11 near me?

Aurora Star Tech Inc. repairs Daikin air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.46 (printed page). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service