KWE Error Code OVERHEATING: Overheating, STB deactivated (Boiler)

Updated · by Aurora Star Tech Inc.

KWE error code OVERHEATING on a boiler means: Overheating, STB deactivated. It is also called KWE diagnostic code OVERHEATING.

Critical severityBoilerVersatronik COMO OT

Homeowner? What KWE code OVERHEATING means for you

Stop and call Your boiler is reporting: Overheating, STB deactivated. This code is a safety shutdown. Turn the boiler off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does KWE error code OVERHEATING mean?

The boiler's STB (safety temperature limiter) has tripped because of overheating.

Applies to: Versatronik COMO OT

Common causes of KWE code OVERHEATING

  • STB deactivation
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other KWE Boiler codes

CodeMeaning
75Outdoor sensor fault
80Room sensor fault
81EEPROM memory error
AIR PRESSUREAir pressure fault
LOCKOUTBoiler lockout, no flame
SERVICEService required
WATER PRESSLow water pressure

All KWE Boiler error codes →

KWE code OVERHEATING: homeowner questions

What does KWE code OVERHEATING mean?

Overheating, STB deactivated. The boiler's STB (safety temperature limiter) has tripped because of overheating.

Is it safe to keep using my boiler with code OVERHEATING?

No. Code OVERHEATING is a safety shutdown, so keep the boiler off until a licensed technician has checked it.

Can I reset KWE code OVERHEATING myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix KWE code OVERHEATING near me?

Aurora Star Tech Inc. repairs KWE boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Versatronik COMO OT installation and operating manual, p. 31. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.