Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

KWE Error Code SERVICE: Service required (Boiler)

Updated · by Aurora Star Tech Inc.

KWE error code SERVICE on a boiler means: Service required. It is also called KWE diagnostic code SERVICE.

Low severityBoilerVersatronik COMO OT

Homeowner? What KWE code SERVICE means for you

Usually minor Your boiler is reporting: Service required. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does KWE error code SERVICE mean?

Service work on the boiler must be completed.

Applies to: Versatronik COMO OT

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other KWE Boiler codes

CodeMeaning
75Outdoor sensor fault
80Room sensor fault
81EEPROM memory error
AIR PRESSUREAir pressure fault
LOCKOUTBoiler lockout, no flame
OVERHEATINGOverheating, STB deactivated
WATER PRESSLow water pressure

All KWE Boiler error codes →

KWE code SERVICE: homeowner questions

What does KWE code SERVICE mean?

Service required. Service work on the boiler must be completed.

Is it safe to keep using my boiler with code SERVICE?

Usually yes. Code SERVICE is normally minor, but if it keeps coming back have it checked.

Can I reset KWE code SERVICE myself?

You can try one reset (power off for 30 seconds, then on). If KWE code SERVICE comes back, the cause is still there and a licensed technician should check it.

Who can fix KWE code SERVICE near me?

Aurora Star Tech Inc. repairs KWE boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Versatronik COMO OT installation and operating manual, p. 31. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977