Allied Furnace: PVC versus ABS connections at the furnace

Updated · by Aurora Star Tech Inc.

PVC versus ABS connections at the furnace on a Allied furnace: Intake and exhaust connections on 92G1UH are PVC. ABS pipe needs transition solvent to join the PVC fitting in the unit.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vent pipe material selection

How to fix pvc versus abs connections at the furnace: step by step

  1. Use PVC primer and PVC solvent cement when running PVC vent pipe.
  2. When using ABS vent, bond to the unit's PVC fitting with transition solvent cement.
  3. Use all-purpose cement only when fittings and pipe are the same material.
  4. Use low-temperature solvent cement in cold weather.
  5. Do not use hammer blows to insert pipe.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Allied Furnace codes

Models

92G1UH92G1UH0450892G1UH0451292G1UH0700892G1UH0701292G1UH0901292G1UH0901692G1UH1101692G1UH1102092G1UH1352095G1UHA93UHA95UH

More other tips for furnace

Source: Allied 92G1UH installation manual, p. 18 (PDF p. 18). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.