Allied Furnace: Preventing exhaust icing in extreme cold

Updated · by Aurora Star Tech Inc.

Preventing exhaust icing in extreme cold on a Allied furnace: Long vent runs through unconditioned space can form ice at the termination below about 20 F (6.7 C) and stop the unit from running.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Exhaust terminations in cold climates

How to fix preventing exhaust icing in extreme cold: step by step

  1. Make sure run times are at least 5 minutes, which clears most icing problems.
  2. If icing persists, install heating cable on the exhaust piping and termination. Heating cable kits are available; check the unit spec sheet for part numbers.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Allied Furnace codes

Models

92G1UH92G1UH0450892G1UH0451292G1UH0700892G1UH0701292G1UH0901292G1UH0901692G1UH1101692G1UH1102092G1UH1352095G1UHA93UHA95UH

More other tips for furnace

Source: Allied 92G1UH installation instructions manual, p. 27. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.