Viessmann DLFSHBH12XAK Error Codes

Updated · by Aurora Star Tech Inc.

Viessmann DLFSHBH12XAK error codes and diagnostic codes. The DLFSHBH12XAK is a Viessmann mini-split in the Viessmann DLFSHB high wall indoor series.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Viessmann DLFSHBH12XAK error codes list

CodeMeaningSeverity
--Indoor units mode conflictLow
APWi-Fi pairing (AP mode)Low
CLFilter cleaning reminder / Active CleanLow
CPRemote switched offLow
d1Demand response signal DR1 receivedLow
d2Demand response signal DR2 receivedLow
d3Demand response signal DR3 receivedLow
dEDemand response input errorLow
dFDefrostLow
E-C-OECO modeLow
EC07Outdoor fan speed out of rangeHigh
EC51Outdoor EEPROM errorHigh
EC52Condenser coil sensor (T3) faultMedium
EC53Outdoor ambient sensor (T4) faultMedium
EC54Discharge temperature sensor (TP/T5) faultMedium
EC56Indoor coil outlet sensor (T2B) faultMedium
EH0AIndoor EEPROM errorHigh
EH0bIndoor PCB to display board communication errorMedium
EH00Indoor EEPROM errorHigh
EH02Zero-crossing signal errorMedium
EH03Indoor fan speed out of rangeHigh
EH30Indoor external fan low voltageMedium
EH31Indoor external fan over voltageMedium
Eh60Room sensor (T1) faultMedium
Eh61Indoor coil sensor (T2) faultMedium
EL0CRefrigerant leak detectedHigh
EL01Indoor / outdoor communication errorHigh
FCForced coolingLow
FH 0dFault - see outdoor unitLow
FH 0PAP mode on / no Wi-Fi kitLow
FPLow-temperature heating (8 C mode)Low
LC01Speed limited by condenser temperatureLow
LC02Speed limited by discharge temperatureLow
LC03Speed limited by currentLow
LC05Speed limited by voltageLow
LC06IPM high temperature / PFC frequency limitMedium
LH00Speed limited by indoor coil temperatureLow
LH07Speed limited by remoteLow
LLControls lockedLow
nANo faultLow
nFFilter replacement reminderLow
OffTimer offLow
OnTimer onLow
PC0ACondenser high temperature protectionMedium
PC0FPFC module protectionHigh
PC0LOutdoor temperature too lowLow
PC00Inverter module (IPM) protectionCritical
PC02Compressor top overheat (OLP)High
PC03Pressure protectionHigh
PC04Inverter compressor drive errorHigh
PC06Discharge temperature protectionHigh
PC08Outdoor over-current protectionHigh
PC10Low AC supply voltageHigh
PC11AC supply voltage protection (over voltage)High
PC12DC bus high voltage / 341 MCE errorHigh
PC40Main chip to compressor drive chip communication errorHigh
PC41Current input detection protectionMedium
PC42Compressor start failureHigh
PC43Compressor phase lossHigh
PC44Zero speed protectionHigh
PC45Compressor drive chip (IR / 341 PWM) failureHigh
PC46Compressor speed out of controlHigh
PC49Compressor over-currentHigh
PH09Anti-cold-air in heatingLow
PH90Evaporator coil too hotMedium
PH91Evaporator coil too coldMedium
SCSelf clean runningLow
SDPower abnormal detectionLow

Troubleshooting the DLFSHBH12XAK

All Viessmann Mini-Split error codes →

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.