Midea Error Code PCA1: Refrigerant pipe condensation protection (Mini-Split)

Updated · by Aurora Star Tech Inc.

Midea error code PCA1 on a mini-split means: Refrigerant pipe condensation protection. It is also called Midea diagnostic code PCA1.

Low severityMini-SplitMidea DLCM(R/H)B multi-zone outdoor

Homeowner? What Midea code PCA1 means for you

Usually minor Your ductless mini-split is reporting: Refrigerant pipe condensation protection. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Midea error code PCA1 mean?

The unit stopped to avoid sweating on the refrigerant pipe. The manual gives no flow chart for this code.

Applies to: DLCMRBH / DLCMHBH multi-zone outdoor units 18-48K (Midea, Carrier, Viessmann Vitocal 200-S)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Midea models that use code PCA1

DLCMHBH24CAKDLCMHBH30DAKDLCMHBH36DAKDLCMHBH48EAKDLCMRBH18BAKDLCMRBH36DAKDLCMRBH48EAK

Other Midea Mini-Split codes

CodeMeaning
PC42Compressor start failure
PC43Compressor phase loss
PC44Zero speed protection
PC45Compressor drive chip (IR / 341 PWM) failure
PC46Compressor speed out of control
PC49Compressor over-current
PH09Anti-cold-air in heating
PH90Evaporator coil too hot
PH91Evaporator coil too cold
SCSelf clean running
SDPower abnormal detection

All Midea Mini-Split error codes →

Midea code PCA1: homeowner questions

What does Midea code PCA1 mean?

Refrigerant pipe condensation protection. The unit stopped to avoid sweating on the refrigerant pipe. The manual gives no flow chart for this code.

Is it safe to keep using my ductless mini-split with code PCA1?

Usually yes. Code PCA1 is normally minor, but if it keeps coming back have it checked.

Can I reset Midea code PCA1 myself?

You can try one reset (power off for 30 seconds, then on). If Midea code PCA1 comes back, the cause is still there and a licensed technician should check it.

Who can fix Midea code PCA1 near me?

Aurora Star Tech Inc. repairs Midea ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLCMRBH/DLCMHBH Multi-Zone Outdoor Service Manual (sold as Midea, Carrier and Viessmann Vitocal 200-S; Viessmann doc 6225551-03, 12/2024), Table 23 Outdoor Unit Error Display p.26. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.