Midea Error Code P0: Inverter module (IPM) fault (Mini-Split)
Midea error code P0 on a mini-split means: Inverter module (IPM) fault. It is also called Midea diagnostic code P0.
Homeowner? What Midea code P0 means for you
Stop and call Your ductless mini-split is reporting: Inverter module (IPM) fault. This code is a safety shutdown. Turn the ductless mini-split off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.
Safe things you can check yourself
- Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
- Check the breaker and the outdoor disconnect; both should be ON.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Midea error code P0 mean?
Same fault as PC00. Shown on the 48K high heat model.
Applies to: DLCMHBH48EAK (48K high heat) only
Midea models that use code P0
DLCMHBH24CAKDLCMHBH30DAKDLCMHBH36DAKDLCMHBH48EAKDLCMRBH18BAKDLCMRBH36DAKDLCMRBH48EAK
Other Midea Mini-Split codes
All Midea Mini-Split error codes →
Midea code P0: homeowner questions
What does Midea code P0 mean?
Inverter module (IPM) fault. Same fault as PC00. Shown on the 48K high heat model.
Is it safe to keep using my ductless mini-split with code P0?
No. Code P0 is a safety shutdown, so keep the ductless mini-split off until a licensed technician has checked it.
Can I reset Midea code P0 myself?
Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.
Who can fix Midea code P0 near me?
Aurora Star Tech Inc. repairs Midea ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- Indoor unit leaking water All brands · Mini-Split
- Poor capacity / high head All brands · Mini-Split
- Water leaking All brands · Mini-Split
- Discharge the inverter capacitors before service Midea · Mini-Split
- Display shows a strange code or does not answer the remote - DLFSHB indoor Midea · Mini-Split
- Multi-zone: one room heats, another will not cool - DLC multi-zone Midea · Mini-Split
- Read live data with the outdoor check button (SW1) Midea · Mini-Split
- Run the automatic wiring / piping correction Midea · Mini-Split
Source: DLCMRBH/DLCMHBH Multi-Zone Outdoor Service Manual (sold as Midea, Carrier and Viessmann Vitocal 200-S; Viessmann doc 6225551-03, 12/2024), Table 24 Outdoor Unit Error Display (48 High Heat only) p.27; diagnosis p.68. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.