Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Midea Error Code nA: No fault (Mini-Split)

Updated · by Aurora Star Tech Inc.

Midea error code nA on a mini-split means: No fault. It is also called Midea diagnostic code nA.

Low severityMini-SplitMidea DLFSHBH wall indoor (DLCM multi-zone)

Homeowner? What Midea code nA means for you

Usually minor Your ductless mini-split is reporting: No fault. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Midea error code nA mean?

No malfunction or protection active.

Applies to: DLFSHBH high wall indoor units 09-24K (Midea / Carrier / Viessmann) on DLC multi-zone or single-zone outdoor units

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Midea models that use code nA

DLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK

Other Midea Mini-Split codes

CodeMeaning
LC03Speed limited by current
LC05Speed limited by voltage
LC06IPM high temperature / PFC frequency limit
LH00Speed limited by indoor coil temperature
LH07Speed limited by remote
LLControls locked
nFFilter replacement reminder
ODU --Outdoor board standby
ODU 00Wiring / piping check finished
ODU CEAutomatic wiring / piping check running
ODU E0Outdoor EEPROM error (outdoor board)
ODU E2Indoor / outdoor communication error (outdoor board)

All Midea Mini-Split error codes →

Midea code nA: homeowner questions

What does Midea code nA mean?

No fault. No malfunction or protection active.

Is it safe to keep using my ductless mini-split with code nA?

Usually yes. Code nA is normally minor, but if it keeps coming back have it checked.

Can I reset Midea code nA myself?

You can try one reset (power off for 30 seconds, then on). If Midea code nA comes back, the cause is still there and a licensed technician should check it.

Who can fix Midea code nA near me?

Aurora Star Tech Inc. repairs Midea ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier MS-DLFSHB-01 High Wall Ductless Service Manual (04/2021), Table 9 p.17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service