Lennox Furnace: EL296UHV: what the display and the diagnostic button are telling you

Updated · by Aurora Star Tech Inc.

EL296UHV: what the display and the diagnostic button are telling you on a Lennox furnace: The furnace control has a seven-segment display and one push button. Normal operation, stored errors, flame current and the unit size are all read from it.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: EL296UHV(X) series

How to fix el296uhv: what the display and the diagnostic button are telling you: step by step

  1. Watch the display with the furnace idle: a blinking dot means idle. C, H, d, h or dF followed by a number means a call is running.
  2. To read stored errors, hold the button until E shows and release. The last 10 codes scroll. Choose c and press again while it flashes to clear them.
  3. To check the flame sensor, hold until F shows and release. Normal is 2.6 microamps or more. 2.5 or less is low. Drop out is 1.1.
  4. Hold until three bars show to go back to normal. Menus time out on their own.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Lennox Furnace codes

Models

Lennox EL195UHNE

EL195UH040NE36BEL195UH060NE36BEL195UH080NE48CEL195UH100NE60C

EL296UHV

EL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60D

Lennox ML180UHE

ML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DK

Lennox SL280UHV

SL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60D

Lennox SL297NV

SL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C

Source: Lennox EL296UHV(X) Unit Information, Corp 1125-L5 (rev. 03/2022), Tables 4-5 (diagnostic modes and LED codes), printed p.32-33. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.