Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Furnace: Recall stored status codes (amber LED furnaces)

Updated · by Aurora Star Tech Inc.

Recall stored status codes (amber LED furnaces) on a Carrier furnace: Replays the stored status codes on the amber LED; codes survive power loss. Two-digit codes are short flashes (first digit) then long flashes (second digit).

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: 59TP6A and 58SB0A/58SB1A furnaces (amber status LED control)

How to fix recall stored status codes (amber led furnaces): step by step

  1. 59TP6A: no thermostat signal, blower-off delays finished, 115 V on, blower door removed
  2. 59TP6A: turn SW1-1 ON and hold the blower door switch closed; up to 7 codes flash, the 8th is always 11 (nothing stored)
  3. 59TP6A: turn SW1-1 OFF, refit the door; steady amber LED = normal
  4. 58SB0A/58SB1A: with no call and delays finished, note the LED state through the sight glass
  5. 58SB0A/58SB1A: briefly pull the wire off the draft safeguard (DSS) switch until the LED goes out, then reconnect; the stored code flashes 4 times (11 = none)
  6. 58SB0A/58SB1A: do not leave the LS or DSS wire off longer than 4 seconds or the blower starts and the stored code is replaced by 33
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Furnace codes

Models

58SB0A/58SB1A

58SB0A045E14--1258SB0A045E17--1258SB0A070E14--1258SB0A070E17--1258SB0A070E17--1658SB0A070E21--1658SB0A090E17--1458SB0A090E21--1658SB0A090E21--2058SB0A090E24--2058SB0A110E21--2058SB0A110E24--2058SB0A135E24--2058SB0A155E24--20

59TP6A

59TP6A040-1059TP6A040-1259TP6A060-1259TP6A060-1459TP6A080-1659TP6A080-2059TP6A100-2059TP6A120-22

More service & test modes tips for furnace

Source: Carrier 59TP6A installation instructions, Troubleshooting / Service and Maintenance, p.76-77; Carrier 58SB0A/58SB1A installation instructions (58SB0A-05SI), p.26 and p.31. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.