Viessmann Error Code F.355: Analogue signal reference check: flame signal at start (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code F.355 on a boiler means: Analogue signal reference check: flame signal at start. It is also called Viessmann diagnostic code F.355.

High severityBoilerVitodens 200-W B2HE

Homeowner? What Viessmann code F.355 means for you

Call a technician Your boiler is reporting: Analogue signal reference check: flame signal at start. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code F.355 mean?

Burner in a fault state.

Applies to: Vitodens 200-W B2HE 85, 120, 150, 199

Common causes of Viessmann code F.355

  • Faulty BCU
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code F.355

B2HE-85B2HE-120B2HE-150B2HE-199

Other Viessmann Boiler codes

CodeMeaning
F.349Air mass flow not detected correctly
F.350Ionization current outside permitted range (BCU)
F.351Ionization current outside permitted range (BCU)
F.352CO limit inside appliance exceeded
F.353Insufficient gas supply, output reduced
F.354Gas modulation valve tolerance outside range
F.357Insufficient gas supply
F.359No ignition spark
F.361No or weak flame signal at burner start
F.366Gas valve supply does not switch off
F.367Gas valve supply does not switch off
F.369Flame loss right after ignition (safety time)

All Viessmann Boiler error codes →

Viessmann code F.355: homeowner questions

What does Viessmann code F.355 mean?

Analogue signal reference check: flame signal at start. Burner in a fault state.

Is it safe to keep using my boiler with code F.355?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code F.355 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code F.355 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code F.355 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Viessmann Vitodens 200-W B2HE 85/120/150/199 Service Instructions 6167 813-24 (09/2026), Fault messages, p.62-73. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.