Viessmann Error Code F.185: Supply temperature sensor / high limit open circuit (Boiler)

Updated · by Aurora Star Tech Inc.

Viessmann error code F.185 on a boiler means: Supply temperature sensor / high limit open circuit. It is also called Viessmann diagnostic code F.185.

High severityBoilerVitodens 200-W B2HE

Homeowner? What Viessmann code F.185 means for you

Call a technician Your boiler is reporting: Supply temperature sensor / high limit open circuit. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code F.185 mean?

Burner in a fault state.

Applies to: Vitodens 200-W B2HE 85, 120, 150, 199

Common causes of Viessmann code F.185

  • Open circuit common supply sensor/high limit
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code F.185

B2HE-85B2HE-120B2HE-150B2HE-199

Other Viessmann Boiler codes

CodeMeaning
F.161BCU data memory access error
F.163BCU memory checksum error
F.180Gas pressure too low
F.182Outlet temperature sensor short circuit
F.183Outlet temperature sensor open circuit
F.184Supply temperature sensor / high limit short circuit
F.299Time and date incorrect
F.342BCU communication error
F.345Temperature limiter tripped, auto restart after cooling
F.346Ionization current calibration error
F.348Gas modulation valve fault
F.349Air mass flow not detected correctly

All Viessmann Boiler error codes →

Viessmann code F.185: homeowner questions

What does Viessmann code F.185 mean?

Supply temperature sensor / high limit open circuit. Burner in a fault state.

Is it safe to keep using my boiler with code F.185?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code F.185 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code F.185 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code F.185 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Viessmann Vitodens 200-W B2HE 85/120/150/199 Service Instructions 6167 813-24 (09/2026), Fault messages, p.62-73. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.