Updated · by Aurora Star Tech Inc.

Viessmann error code F.13 on a boiler means: Outside temperature sensor open circuit. It is also called Viessmann diagnostic code F.13.

Low severityBoilerVitodens 200-W B2HE

Homeowner? What Viessmann code F.13 means for you

Usually minor Your boiler is reporting: Outside temperature sensor open circuit. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code F.13 mean?

Control behaves as if outside temperature were 0 C (32 F).

Applies to: Vitodens 200-W B2HE 85, 120, 150, 199

Common causes of Viessmann code F.13

  • Open circuit on outside sensor
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code F.13

B2HE-85B2HE-120B2HE-150B2HE-199

Other Viessmann Boiler codes

CodeMeaning
Connection errorDisplay link lost to HMU
F.5Sensor circuit fault at plug 33 (X6)
F.7DHW storage tank sensor open circuit
F.8DHW storage tank sensor short circuit
F.11Solar collector sensor open circuit
F.12Solar collector sensor short circuit
F.14Outside temperature sensor short circuit
F.15Storage tank sensor open circuit (solar/backup)
F.16Storage tank sensor short circuit (solar/backup)
F.29Low loss header sensor open circuit
F.30Low loss header sensor short circuit
F.49Flue gas temperature sensor open circuit

All Viessmann Boiler error codes →

Viessmann code F.13: homeowner questions

What does Viessmann code F.13 mean?

Outside temperature sensor open circuit. Control behaves as if outside temperature were 0 C (32 F).

Is it safe to keep using my boiler with code F.13?

Usually yes. Code F.13 is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code F.13 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code F.13 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code F.13 near me?

Aurora Star Tech Inc. repairs Viessmann boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Viessmann Vitodens 200-W B2HE 85/120/150/199 Service Instructions 6167 813-24 (09/2026), Fault messages, p.62-73. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.