Viessmann Water Heater: Heat transfer medium requirements
Heat transfer medium requirements on a Viessmann water heater: The heat coil medium must be potable water or substances FDA-recognized as safe. It must also be non-toxic with a toxicity class of 1. Keep its pressure below the minimum operating pressure of the potable water system, and limit it to a maximum of 30 psig with an approved safety or relief valve.
Applies to: Vitocell 100-V CVWC
How to fix heat transfer medium requirements: step by step
- Use potable water or an FDA-safe, non-toxic fluid in the heating circuit.
- Keep the heat transfer medium pressure below the domestic water minimum operating pressure.
- Limit the heat transfer medium to 30 psig maximum with an approved safety or relief valve.
If the unit shows an error code, look it up: Viessmann Water Heater codes
Models
Vitocell 100-V CVWC 53 USG (200 L)Vitocell 100-V CVWC 66 USG (250 L)Vitocell 100-V CVWC 79 USG (300 L)
More other tips for water heater
Source: Vitocell 100-V CVWC installation manual, p. 2. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.