Other: Mini-Split tips (part 5 of 8)

Updated · by Aurora Star Tech Inc.

Short, practical technician tips on other for mini-split. Check each one against the manual for your exact model before acting.

Water collector and refrigerant sensor removal

Carrier · D5FSOAH, sizes 06K to 18K

Remove the water collector first, then the refrigerant sensor. Remove the panel before starting.

  1. Remove the panel.
  2. Remove the 5 screws and take out the water collector.
  3. Remove the 2 screws and take out the refrigerant sensor.

Water pump removal

Carrier · D5FSOAH, sizes 06K to 18K

Remove the panel and water collector before the pump.

  1. Remove the panel and water collector.
  2. Remove the 2 screws and take out the water pump assembly.
  3. Loosen the spring.
  4. Remove the drain pipe.

Which performance data is tested and which is simulated

Carrier · D5CMHA non-ducted performance tables

Extrapolated tables mark only the highlighted values as tested. All other values are simulated and are for reference only.

Wired and third-party control options

Carrier · Indoor unit controls

Optional wired controller and 24 V interface are available for control of the indoor unit.

  1. Use the optional wired controller kit: connect its cable between controller and indoor unit terminal.
  2. Use the optional 24 V interface to control the ductless system from a third-party thermostat.

Wired and wireless controller options

Carrier · Indoor unit controls

The unit can be run by three methods. The wired controller KSACN1401AAA is included and is non-polarity; it has an infrared receiver and works with the wireless remote. The wireless remote is included and does the same functions as the wired controller. A third-party heat pump thermostat is not included and connects through the built-in 24V interface. Under normal conditions the fan speed, swing and temperature cannot be changed by the remote. Live heating requires a wire controller with the AXU function.

Wired and wireless remote control

Carrier · Console indoor units

Remote control options for the console units.

  1. The wireless infrared remote can control more than one unit.
  2. The optional wired controller connects to the indoor unit terminal and can show °F or °C in 1° steps.
  3. Use the extension wire (RCD part 17401204000769) to lengthen the wired controller cable.

Wired controller connection (CN41)

Carrier · Wired controller KSACN1401AAA

CN41 connects to the KSACN1401AAA wired controller only, using field-supplied RS-485 wire.

  1. Use #16 or #18 AWG shielded stranded wire for the controller link.
  2. Connect only to CN41.

Wired controller connection (CN45)

Carrier · D5FCFAH

CN45 connects the KSACN1401AAA wired controller using field-provided RS-485 wire only.

  1. Use #16 or #18 AWG shielded stranded wire.
  2. Connect to CN45 only with RS-485 wire.

Wired controller wiring notes

Carrier · D5FSHA with optional wired controllers

The wired controller connects to the indoor unit main board in one of two ways depending on the controller.

  1. For the KSACN1401AAA, connect to the 12V XYE or CN connection on the indoor main control board (Option A).
  2. For the KSACN1201AAA, connect to the 5-wire modular whip on the indoor display board CN port.
  3. Follow the controller's own installation manual for full details.

Work safely on flammable refrigerant systems

Carrier · All D5FCFAH units

The refrigerant is flammable. Control ignition sources and use approved leak detection.

  1. Check the work area with a refrigerant detector before and during work.
  2. Use only detectors suitable for flammable refrigerant that do not spark.
  3. Do not use a halide torch or any naked flame to find leaks.
  4. Remove all ignition sources if a leak is suspected.
  5. Keep a dry powder or CO2 extinguisher near the charging area when hot work is done.
  6. Keep ventilation open during the work.

Discharge the inverter capacitors before service

Midea · DLCM(R/H)B multi-zone outdoor units with DLFSHBH high wall indoor units (Midea, Carrier, Viessmann)

The big electrolytic capacitors on the outdoor board stay charged after power-off.

  1. Turn power off and lock out.
  2. Put a resistor of about 100 ohm 40 W (or a soldering iron plug) across the + and - capacitor terminals before touching the board.

46 F (8 C) heating freeze protection

Viessmann · HEATING mode freeze protection

When the compressor runs, the indoor fan runs without the anti-cold air function. When the compressor is off, the indoor fan is off. The owner manual Freeze Protection section explains how to enable this feature.

  1. Enable the 46 F (8 C) heating feature using the owner manual Freeze Protection instructions.

Agency listings and coil testing

Viessmann · DLCURA outdoor units

The unit meets ANSI/ASHRAE 15 and the NEC. It is evaluated to UL 60335-2-40 and listed in the CEC directory. The cabinet is rated for a 500-hour salt spray test. Air-cooled condenser coils are leak tested at 550 psig.

Air filter and carbon filter care

Viessmann · Vitocal IND-F floor console, Size 12 (12XAK)

Clean the air filter monthly. Wash the carbon filter every 6 months. The manufacturer recommends replacing it yearly.

  1. Turn off the breaker before opening the front panel.
  2. Open the front panel and remove the air filter.
  3. Remove the carbon filter by holding the frame tabs and releasing the four claws.
  4. Vacuum the air filter with the air-in side facing up, or wash it in water with the air-in side facing down.
  5. For heavy dust, use a soft brush and mild detergent, then dry in a cool place.
  6. Refit the filters as they were and close the front panel. Never run the unit without the air filters.

Air sweep and louver settings

Viessmann · DLFSCBH and DLFLCBH

The indoor unit has a motor driven vertical air sweep and motor driven louvers. The louvers adjust for 2, 3 or 4 way discharge. The air sweep operation is user selectable.

Anti-static protection for electrical parts

Viessmann · DLFSOAH09XAK, DLFSOAH18XAK

Wear anti-static gloves when handling the electronic control box and control boards.

  1. Put on anti-static gloves before touching the electrical parts.

AUTO mode on multi-zone systems

Viessmann · All indoor units in multi-zone systems

AUTO changeover is meant for single-zone use. On multi-zone systems it can put an indoor unit into STANDBY, shown as two dashes (--), which keeps it off until all indoor units run the same mode (COOL or HEAT). HEAT is the priority mode, and simultaneous HEAT and COOL is not allowed.

  1. On multi-zone systems, set all indoor units to the same mode (COOL or HEAT).
  2. Use AUTO only on single-zone installs.

AUTO-RESTART after power failure

Viessmann · Power restore

An auto-restart module stores the settings before a power loss and resumes them 3 minutes after power returns (SWING excluded). If FORCED COOLING was stored, the unit runs COOLING for 30 minutes then AUTO at 75°F (24°C). If the unit was off and must start, the compressor delays 1 minute; otherwise it waits 3 minutes.

Battery life and when to replace batteries

Viessmann · Wireless remote control

Average battery life under normal use is about 6 months. Remove batteries if the remote will sit unused for several weeks to prevent leakage damage.

  1. Replace batteries when the indoor unit does not give an audible beep after a remote command.
  2. Replace batteries if the remote's Transmission Indicator does not light.
  3. Remove batteries if the remote will not be used for several weeks.

Board measurement procedure

Viessmann · Outdoor and indoor control boards

Measure board signals with power on only when needed. Pulsating DC signals should move constantly when a signal is present.

  1. Disconnect main power.
  2. Remove outdoor top cover (outdoor board) or front and control box covers (indoor board).
  3. Reconnect power and probe inputs and outputs with the multimeter; red probe to hot signal, black to ground or negative.
  4. Disconnect main power before reinstalling any board.

Boost mode for faster temperature change

Viessmann · Wireless remote control

BOOST helps the unit reach the set point in the shortest possible time.

  1. Press BOOST on the remote to reach the preset temperature faster.

Built-in protections on DLCLRC units

Viessmann · DLCLRC outdoor units

The control board stops the unit and shows an error code when it detects abnormal conditions. Protections listed include compressor overcurrent and overload, high discharge temperature, IPM module, and low voltage protection, plus a 3 minute compressor time delay.

  1. Check the error display on the indoor or outdoor control for the code.
  2. Look up the code in the manual's error code table if one is provided for this model.
  3. Do not bypass the compressor time delay; wait out the 3 minute delay before restarting.

Buried refrigerant pipe warning

Viessmann · Refrigerant piping

If any section of pipe is buried, there must be a vertical rise to prevent refrigerant migration and slugging.

  1. Do not bury more than 36 in (914 mm) of refrigerant pipe.
  2. Provide at least 6 in (152 mm) of vertical rise to the outdoor unit valve connections.

Buried refrigerant piping limits

Viessmann · DLFSHC refrigerant piping

Do not bury more than 36 in (914 mm) of refrigerant pipe. If any section is buried, it needs a 6 in (152 mm) vertical rise to the outdoor unit valve connections. Excess buried length can let refrigerant migrate to the cold section and cause slugging that may damage the compressor at start-up.

  1. Limit buried refrigerant pipe to 36 in (914 mm) maximum.
  2. If any pipe is buried, provide a 6 in (152 mm) vertical rise to the outdoor valve connections.

Check the airflow and table title before using a performance value

Viessmann · D5CSRA cooling performance tables, pages 64 to 72

Several performance tables appear on the same page and carry similar layouts. The airflow in CFM and the indoor unit type decide which block to use. A value from the wrong airflow or indoor unit will give a wrong capacity or power reading.

  1. Confirm the indoor unit model and capacity size before reading any matrix.
  2. Confirm the airflow setting on site matches the CFM value of the block.
  3. Compare the measured outdoor and indoor conditions with the row and column headings before reading TC, S/T or PI.

CLEAN (self-clean evaporator) function

Viessmann · Sizes 18 to 24

Available on sizes 18 to 24 only. Cleans and dries the evaporator. Only works in COOL or DRY mode.

  1. Press CLEAN in COOL or DRY mode to start.
  2. Cycle runs 16 minutes, then the unit shuts off by itself.
  3. Press CLEAN during the cycle to cancel and turn off the unit.

Clean the air filter

Viessmann · Indoor unit air filter

Clean every two weeks, or more often in dusty areas. Replace the filter if it is heavily clogged and cannot be cleaned. Disconnect power first, except when only cleaning the filter.

  1. Press the circular position to open the two screw covers, then remove the two screws.
  2. Hold and open the air grille, then remove the air filter.
  3. Clean with a vacuum cleaner (intake side facing up) or with clean water (intake side facing down). For heavy dust, use a soft brush and natural detergent, then dry in a cool place.
  4. Do not dry the filter in direct sunlight or near heat or fire.
  5. Re-install the filter and reset the air grille.

Cleaning precautions for the indoor unit

Viessmann · Indoor unit exterior and interior

Water and chemicals can damage the unit and create electrical hazards.

  1. Turn off the indoor unit circuit breaker before cleaning.
  2. Use only a soft dry cloth, or a cloth with warm water (not above 104°F / 40°C) on the front panel.
  3. Do not use chemicals, benzene, paint thinner or polishing powder.
  4. Do not wash the unit under running water or use water inside the unit.

Cleaning the coil and front panel

Viessmann · Vitocal IND-F floor console, Size 12 (12XAK)

Clean the coil at the start of each cooling season. Use only mild methods on the panel.

  1. Clean the indoor coil with a vacuum or long-bristle brush to avoid damaging the fins.
  2. Wear cut protection when cleaning the coil fins.
  3. Wipe the front panel with a soft, dry cloth.
  4. Do not use water hotter than 105°F (40.6°C), do not pour water onto the fan coil, and do not use abrasive or petroleum cleaners.

Communication and wiring hazards

Viessmann · DLCURA outdoor units

Wiring safety points from the manual.

  1. Make sure every wire is tightly connected. Loose wiring can overheat the terminal or cause a malfunction.
  2. Keep all wires away from the refrigerant tubing, compressor and moving parts.
  3. Provide a disconnect within sight of and readily accessible from the unit.
  4. Route the connecting cable through the hole in the conduit panel.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.