Other: Heat Pump tips (part 4 of 5)
Short, practical technician tips on other for heat pump. Check each one against the manual for your exact model before acting.
Ice build-up on outdoor unit
Viessmann · Vitocal 100-AW AM2V outdoor unit
Ice in the condensate pan or fan area can damage the unit.
- Do not use mechanical items or aids to remove ice.
- Check the refrigerant circuit for leaks before using any electric heating appliance nearby, and make sure the heater is not an ignition source.
- Where ice builds up often, fit fan ring heating suitable for R32 and/or an electric ribbon heater in the condensate pan (accessory or factory-fitted).
Installation room and location
Viessmann · Vitocal 100-WA
Place the unit in a heated indoor area near a floor drain and an outside wall where practical.
- Keep the mechanical room at or above 60°F (15°C).
- Locate the unit near a floor drain.
- Place the unit near an outside wall so ground loop connections are easy.
- Do not install in an area subject to freezing.
Installation rules for A2L refrigerant rooms
Viessmann · Vitocal 100-WA
Rules for ignition sources and room size where A2L refrigerant appliances are installed or ducted.
- If the room is smaller than the minimum area (Amin) or has an effective dispersal volume below the minimum, keep the room free of continuously operating open flames and other potential ignition sources.
- A flame-producing device may stay in the same space only if it has an effective flame arrest.
- Confirm a leak detection system is installed. The unit must stay powered except during service.
- Use non-sparking tools for A2L refrigerants and check for leaks with a refrigerant detector before and during installation.
Interconnection cable length
Viessmann · Indoor unit to outdoor unit wiring
Short cables let leaked refrigerant reach the building interior.
- Use an electrical connecting cable between indoor and outdoor unit of at least 3 m.
Isolate power before service
Viessmann · DLCLRC sizes 36K-58K
Before installing, modifying or servicing, the main electrical disconnect must be OFF. There may be more than one disconnect. Lock out and tag each switch with a suitable warning label.
- Switch off every main disconnect for the system.
- Lock out and tag each switch.
- Verify the unit is de-energized before touching wiring.
Isolate power before service work
Viessmann · Vitocal 100-WA
There are no user serviceable parts on the heat pump. Service must be done by a licensed contractor.
- Deactivate the main power supply to the heat pump, the heating system and all external controls.
- Take precautions so power cannot be switched on accidentally during service.
Limit the tilt angle when moving the outdoor module
Viessmann · Handling the outdoor module
Excess tilt can send compressor oil into the refrigerant circuit and cause a failure at start-up.
- Do not tilt the module more than 30°.
- If a tilt beyond 30° is needed, limit it to 45° for no more than about 4 minutes.
Live components: wait before opening covers
Viessmann · Indoor and outdoor units
Some PCB components stay live after power is removed.
- Switch off and isolate the power supply, and safeguard it against reconnection.
- Wait at least 4 minutes after power-off before removing any covers, so the voltage fully drops out.
- Wear suitable personal protective equipment.
Lock out power before working on the system
Viessmann · All DLCURA units
Turn off the main electrical disconnect before installing, modifying or servicing. There may be more than one disconnect. Lock and tag each one.
- Switch off the main disconnect.
- Check for additional disconnects.
- Lock out and tag each switch with a warning label.
Louver position memory
Viessmann · DLFSOAH09XAK, DLFSOAH18XAK
After power is restored, the louver returns to the angle set by the user if it is within the allowed range. If the angle is outside the range, the unit uses the maximum allowed angle. If power fails or the unit is shut down during TURBO, the louver returns to the default angle.
Main menus on the display
Viessmann · Vitocal 100-AW AM2V indoor unit
Home screen shows basic heat pump parameters. Diagnostics shows input and output signals. Settings holds user adjustable parameters. Service menu is for configuration and is protected by an access code. Time Schedule Override lets the owner override the active heating or cooling without changing the schedule.
- Use Diagnostics to view heat pump input and output signals.
- Use Settings to adjust user parameters and schedules.
- Use Time Schedule Override for a temporary change to the active function.
Maintenance and installation precautions
Viessmann · Vitocal 100-WA
Key service precautions for the unit and its plumbing.
- Keep chemicals that corrode copper out of the water loops and out of the equipment room.
- Keep the unit out of freezing and unconditioned spaces; it is not for outdoor installation.
- Cover the unit during dust-producing work and never run it during construction.
- Never lay the unit on its side or drop it; check refrigerant charge after reinstalling.
- Use copper tubing only for repairs to the water plumbing; do not use PVC, CPVC, PEX or other plastic pipe.
- Check the drain pans and condensate tubing at both ends during annual maintenance.
- Keep a service record with this manual.
Never pressurize with oxygen-containing gas
Viessmann · DLCLRC refrigerant circuit service
Never use air or gases containing oxygen for leak testing or for operating refrigerant compressors. Pressurized mixtures containing oxygen can explode.
- Use dry nitrogen or an approved refrigerant-compatible gas for leak testing.
- Do not pressurize the system with air.
Never pull a vacuum with the compressor or use oxygen
Viessmann · DLCLRC outdoor units
The compressor is not a vacuum pump, and oxygen-containing gas must never be used for leak testing or operation.
- Do not run the system compressor as a vacuum pump.
- Do not use air or any oxygen-containing gas for leak testing or to operate refrigerant compressors.
- Break vacuum with dry nitrogen only.
Order parts with the serial number
Viessmann · Vitocal 100-WA
Some replacement parts are not reverse compatible with earlier versions.
- Find the 16-digit serial number on the Vitocal rating plate.
- Give the serial number when ordering replacement parts.
Ordering parts requires the 16-digit serial number
Viessmann · Vitocal 100-WA
The 16-digit serial number is on the Vitocal rating plate. Provide it when ordering replacement parts, because some parts are not reverse compatible with previous versions.
- Read the 16-digit serial number from the rating plate.
- Give the serial number when ordering parts.
Ordering replacement parts
Viessmann · Vitocal 100-AW AM2V indoor and outdoor units
Replacement parts need the 16-digit serial number from the indoor or outdoor unit rating plate. Some new parts do not fit earlier versions of the AM2V.
- Read the 16-digit serial number from the indoor or outdoor unit rating plate.
- Give the serial number when ordering parts.
- Check part compatibility before fitting a part to an older unit.
Outdoor temperature operating limits
Viessmann · Outdoor unit, all models
The air-to-water heat pump only runs efficiently within a set outdoor temperature range. Outside the upper or lower limit it switches off periodically and the controller shows a notification. The controller then brings in available auxiliary heating (e.g. electric auxiliary heater) for space heating and DHW.
- Check the outdoor temperature range against the design conditions for the building.
- If the controller reports the heat pump is off, confirm the outdoor temperature is outside the limits before investigating further.
Piping and air connection locations
Viessmann · Vitocal 100-WA
Connection legend for the Vitocal 100-WA. Letters refer to the piping connections diagram in the manual.
- A: return to ground loop.
- B: supply from ground loop.
- C: condensate line connection.
- D: return air.
- E: DHW supply to the DHW tank.
- F: DHW tank return to the DHW desuperheater.
- G: supply air.
Power and communication wiring between units
Viessmann · All D5CSRA systems
Size wires per NEC or CEC and local codes, using the MCA and MOP values from the electrical data table to size the wires and the disconnect fuse or breaker. Power and communication run as 14/3 field wire: two high-voltage AC wires, one communication wire and one ground. The wiring is polarity sensitive. BX cable is not recommended. In high EMF areas with communication problems, 14/2 stranded shielded wire can replace L2 and S, with the shield grounded at the outdoor unit only. Power is a single-point connection to the outdoor unit.
- Size wires and the disconnect using the MCA and MOP values.
- Run 14/3 power and communication wire with two AC wires, one communication wire and one ground.
- Keep polarity correct between indoor and outdoor units.
- Do not use BX cable.
- In high EMF areas, use 14/2 stranded shielded wire and ground the shield at the outdoor unit only.
Power wiring checks
Viessmann · All Vitocal 100-WA units
Wrong wiring can injure people and damage the unit.
- Confirm L1, L2 and G are not interchanged.
- Ground the control.
- Use a licensed electrician for line voltage; the certified contractor may do Class 2 low-voltage wiring.
Preparing for service on flammable refrigerant systems
Viessmann · Vitocal 100-WA, R-454B refrigerant
Charging and handling precautions before work starts.
- Make sure charging equipment is not contaminated by other refrigerants.
- Keep hoses and lines as short as possible to limit the refrigerant held in them.
- Keep cylinders in the correct position as per their instructions.
- Earth the refrigerating system before charging it with refrigerant.
- Label the system when charging is complete.
- Take great care not to overfill the refrigerating system.
- Do not install auxiliary devices that are potential ignition sources in the ductwork. Hot surfaces above 700°C (1292°F) and electrical switching devices are examples. Only devices declared suitable for R-454B may be installed in connected ductwork.
- Do not use means to speed up defrosting or cleaning other than those the manufacturer recommends.
- Store the appliance in a room without continuously operating ignition sources such as open flames, operating gas appliances or electric heaters.
- Do not pierce or burn the refrigerant circuit. Refrigerants may have no odour.
Provide clearance for service and ductwork
Viessmann · Vitocal 100-WA
Clearances are needed for service access, piping, ductwork and wiring.
- Keep at least 24 in. (600 mm) of service clearance.
- Leave room for piping, ductwork and electrical connections.
- If installed in a closet, provide adequate return air flow to the unit.
Purge air from the heat pump system
Viessmann · Heating water circuit
Air must be removed through air vents in the system supply. Restrictive piping can trap air and prevent full purging.
- Install air vents in the system supply.
- Route supply and return lines so no restrictive piping can trap air.
Qualification and work area
Viessmann · Vitocal 100-AW AM2V service work
Work affecting safety must be done by competent persons, under a controlled procedure.
- Only competent, licensed persons may open the refrigerant circuit, sealed components or ventilated enclosures.
- Work in the open or in a well-ventilated area and avoid confined spaces.
- Keep a dry powder or CO2 extinguisher next to the charging area when doing hot work.
- Keep all possible ignition sources, including smoking, well away from the work site.
Ratings lookup for crossover systems
Viessmann · Outdoor unit sizes 18K to 60K
AHRI ratings for combinations with approved furnaces or cased coils are listed in the AHRI directory.
- Check the AHRI directory for ratings certificates.
- Check the manufacturer's rating database for additional system combinations.
Reading system information and software versions
Viessmann · Vitocal 100-AW AM2V
The System Information menu shows software versions for the indoor unit interface and control board, and lets you restart the indoor unit.
- Open the System Information menu.
- Read S.W. Ver. HMI for the indoor unit interface software.
- Read ODU Software Version for the outdoor unit.
- Read S.W. Ver. PCB for the control board software.
- Use Control Reboot IDU to restart the indoor unit if needed.
Reading the indoor unit model number
Viessmann · DLFSHCH high wall indoor units
The model code breaks down into: DLF = indoor unit, S = model, voltage (J = 115-1-60, K = 208/230-1-60), H = high wall fan coil, H = heat pump, then nominal capacity (06 = 1/2 ton up to 36 = 3 tons), then major series (A = standard) and variation (X = 1:1, max one fan coil per outdoor unit).
Reduce vibration and noise
Viessmann · Vitocal 100-WA
Heat pumps, pumps and fans transmit noise and vibration into the building.
- Use flexible ducting or duct connectors to separate the unit from the building.
- Place a shock-absorbing pad under the heat pump and associated pumps.
- Keep the unit clear of water spray and splashing.
Refrigerant circuit work: checks before starting
Viessmann · Vitocal 100-AW AM2V refrigerant circuit
Checks needed before opening the refrigerant circuit so the risk of ignition is minimised.
- Switch off power to the indoor and outdoor units and confirm the system is dead; there may be more than one power circuit.
- Check the refrigerant circuit for leaks.
- Ventilate well, especially near the floor, and keep it ventilated for the whole job.
- Check the area around the heat pump for flammable material and ignition sources, and remove them.
- Check the surrounding air with a sparkless, sealed R32-suitable refrigerant detector before, during and after the work.
- Inform maintenance staff and people nearby about the work.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.