Gateway purpose

Viessmann · Versatronik 511 and 511D

The gateway translates between the boiler control and a LON-capable DDC/BMS system. It can sit inside a control panel or stand alone.

Gateway status light meaning

Viessmann · Versatronik 515 NR2/BACIP and 515D NR2/BACIP gateways

The gateway status light shows communication status.

  1. Light flashing: communication is active.
  2. Light solid or off: no communication. Check the wiring and the boiler control connection.

Getting the short help guide

Viessmann · Vitotrol 300A

The help key shows a short guide on the controls and heating circuit selection.

  1. From the standard display, press the ? key.
  2. From anywhere in the menu, press the back key until the standard display shows, then press ?.

Hand over operating and service documents to the owner

Viessmann · Vitocrossal 200 CI2 boilers

The system manufacturer must give the operator the operating instructions and train them on the system. Include any accessories such as remote controls. Hand over the operator section and keep the heating contractor section. Installation instructions are not required after installation.

  1. Complete the customer information and separate the operator section from the heating contractor section.
  2. Hand over the operator section for safekeeping.
  3. Keep the heating contractor section.
  4. File all parts lists, operating and service instructions in folders and hand them to the operator.
  5. Explain the required maintenance to the operator.

Handle fiberglass wool and ceramic fiber safely

Viessmann · Fiberglass wool and ceramic fiber parts such as the combustion chamber door insulation

Airborne fibers from fiberglass wool and ceramic fiber parts are a possible cancer hazard and cause irritation. Use proper protection when handling these materials. If eyes are irritated, flush with lukewarm water for at least 15 minutes.

  1. Avoid breathing dust and avoid contact with skin and eyes.
  2. Wear a NIOSH approved dust/mist respirator.
  3. Wear long-sleeved loose clothing, gloves and eye protection.
  4. Wash work clothes separately and rinse the washer well.
  5. Move the person to a dust-free area if breathing irritation develops.
  6. Wash skin with soap and water if irritated. Do not rub or scratch.

Handle the board as static sensitive

Viessmann · Versatronik 515 and 515D gateways

Static can damage components inside the control. Take steps to prevent static build-up before working inside the unit.

  1. Use static precautions before handling or working inside the control.

Handle the control board with ESD precautions

Viessmann · Versatronik 505 and 505D

Static-sensitive components can be damaged by poor handling or work inside the control. Take all reasonable steps to prevent static build-up.

  1. Use static-control precautions before working inside the control.

Handle the control boards with static precautions

Viessmann · Versatronik 501 and 501D gateways

Static can damage the components inside the control. Take all reasonable steps to prevent static build-up during handling or work.

  1. Use static precautions before handling or working inside the control.

Handle the electronics with static precautions

Viessmann · Versatronik 581 and 581D

Static can damage the components inside the control.

  1. Take measures to remove static build-up before touching the internal circuitry.
  2. Handle components carefully to avoid damage.

Handling fiberglass and ceramic fiber insulation

Viessmann · Insulation and combustion chamber door refractory

Insulation and combustion chamber materials can be a cancer hazard when inhaled.

  1. Read the fiberglass and ceramic fiber warning on p. 3 before handling insulation.
  2. Use a NIOSH approved dust/mist respirator and long-sleeved clothing, gloves and eye protection.
  3. Avoid sawing, blowing, tear-out or spraying that creates airborne fibers without added protection.
  4. Wash work clothes separately and rinse the washer thoroughly.

Handling fiberglass and ceramic fiber materials

Viessmann · Vitocrossal 300 CU3A 26 to 199

Breathing fiberglass wool or ceramic fiber dust can cause cancer risk and irritation to the lungs, skin and eyes.

  1. Wear a NIOSH approved dust/mist respirator, long sleeves, gloves and eye protection.
  2. Wash work clothes separately and rinse the washer well.
  3. Flush eyes with water if dust gets in them; wash skin with soap and warm water.

Handling fiberglass wool and ceramic fiber insulation

Viessmann · Vitorond 200 VD2A

Fiberglass wool and ceramic fiber materials in the boiler (for example the combustion chamber door insulation) can cause respiratory, skin and eye irritation and are a possible cancer hazard when airborne. Use the protection below when handling or cutting them.

  1. Wear a NIOSH-approved dust/mist respirator.
  2. Wear long-sleeved loose clothing, gloves and eye protection.
  3. Avoid breathing dust and avoid contact with skin and eyes.
  4. Wash work clothes separately and rinse the washer thoroughly.
  5. Expect airborne fibers from sawing, blowing, tear-out or spraying; use extra protection.
  6. Eyes: flush with lukewarm water for at least 15 minutes, holding the eyelids open.
  7. Skin: remove soiled clothing, wash with soap and water, and do not rub or scratch.

Handling fiberglass wool and ceramic fiber materials

Viessmann · Vitocrossal 300 CA3B Series 2.5 to 6.0

Fiberglass and ceramic fiber parts can cause cancer, and skin, eye and breathing irritation. Protect yourself when you work near them.

  1. Wear a NIOSH approved dust/mist respirator.
  2. Wear long-sleeved loose clothing, gloves and eye protection.
  3. Avoid breathing dust and avoid contact with skin and eyes.
  4. Wash work clothes separately from other clothing and rinse the washer well.
  5. Expect extra protection needs when sawing, blowing, tearing out or spraying.
  6. If eyes are irritated, flush with lukewarm water for at least 15 minutes. Do not rub them.
  7. If skin is irritated, remove soiled clothing and wash with soap and cold water.

Handover to the owner

Viessmann · Final commissioning and handover

The installer must review the equipment, safety requirements and shutdown procedure with the operator or owner. Annual professional service is required before each heating season.

  1. Review the equipment, safety precautions and shutdown procedure with the owner.
  2. Explain that annual professional service is needed before the heating season starts.
  3. Leave all literature at the site and tell the owner where it is kept.

Handover to the system owner

Viessmann · Vitodens 222-F, B2TB 19, 35, 68, 125

Before leaving, the installer must show the system operator how the equipment works, how to shut it down in an emergency, and that annual professional service is needed before each heating season.

  1. Explain the system operation sequence to the owner.
  2. Demonstrate emergency shut-down and state what to do and what not to do.
  3. Tell the owner annual professional service is required before the heating season starts.
  4. Leave all literature near the boiler and complete the Maintenance Record.

Heat DHW once outside the time program

Viessmann · Vitocrossal 300 CA3B with Vitotronic 300 GW6C

Forces a one-time DHW heat cycle. The operating program must be set to Heating and DHW or DHW only for at least one heating circuit. Turn comfort mode on and then straight off so central heating does not run at standard room temperature.

  1. Confirm that Heating and DHW or DHW only is set for at least one heating circuit.
  2. Enable comfort mode for that circuit.
  3. Immediately disable comfort mode.

Heat DHW once without rooms time program

Viessmann · Vitotronic 300-K

Used when DHW is needed once but the rooms should stay unheated. Sets the DHW temperature to 50°F (10°C) and disables party mode afterwards.

  1. Make sure Heating and DHW or Only DHW is set for at least one heating circuit.
  2. Open the extended menu and select Heating.
  3. Select Heating program, then Heating and DHW.
  4. Go back until the menu for DHW is shown.
  5. Select DHW, then Set DHW temperature.
  6. Set it to 50°F (10°C).
  7. Afterwards, set Party mode to OFF to prevent central heating at standard room temperature.

Heat DHW once, outside the time program

Viessmann · DHW tank

Comfort mode must be turned on and then off again straight away. This heats the DHW once without starting central heating at standard room temperature. The operating program Heating and DHW or DHW only must be set for at least one heating circuit.

  1. Turn on Comfort mode (see manual p. 26).
  2. Turn Comfort mode off again straight away.

Heat slope adaptation (ON/OFF)

Viessmann · Versatronik COMO OT

Automatic heat slope adjustment is active only with the outdoor sensor connected. It runs only below 8°C outdoor and with the room below 18°C. If the room does not reach the target within 4 hours, the adaptation is cancelled and the warning indicator flashes. It then repeats the next day.

  1. Connect the outdoor sensor to terminals 5 and 6.
  2. Turn the adaptation on.
  3. Allow the system to run through the adaptation.
  4. If the warning indicator flashes, let the next day's adaptation run.

Heating circuit and display symbols

Viessmann · Vitocrossal 300 CU3A with Vitotronic control

HC1, HC2 or HC3 appear in the header only when the system has two or three heating circuits; single-circuit systems show no HC name. Other symbols appear depending on system version and operating state.

  1. Select HC1, HC2 or HC3 in the standard menu to choose which circuit displays.
  2. Use ZC1, ZC2 or ZC3 to display a zone circuit selected in the standard menu.
  3. Symbols include frost protection, central heating standard or reduced temperature, party and economy mode, solar pump running, burner on, service message and fault message.

Heating circuit and mixer terms

Viessmann · Vitotrol 300A

Short definitions of heating circuit terms used in this manual.

  1. Heating circuit: sealed loop between the boiler and the radiators, with water circulated by the heating circuit pump.
  2. Mixer: mixes boiler water with cooled return water so the flow temperature matches demand. The control unit adjusts the flow temperature through the mixer.

Heating circuit extension (heating circuits 2 and 3) legend

Viessmann · Heating circuit extension accessory

The accessory extension for heating circuits 2 and 3 uses supply temperature sensors, heating circuit pumps, mixing valve motors and relays K1 to K6.

Heating circuit labelling

Viessmann · Vitotronic 300-K heating circuits

With one heating circuit without a mixing valve and one or two heating circuits with mixing valves, the non-mixed circuit is called 'Heating circuit 1'. Mixed circuits are 'Heating circuit 2' or 'Heating circuit 3'. If a custom name was entered, that name appears together with HC1, HC2 or HC3.

Heating circuit names

Viessmann · Heating circuit naming

Heating circuits default to Heating circuit 1, 2 and 3. Names are changed in the Operating Instructions.

  1. Refer to the Operating Instructions to enter names for heating circuits.

Heating circuit pump

Viessmann · Vitodens 200-W B2HA

The heating circuit pump circulates the heating water in the heating circuit.

Heating circuit pump OFF setting can freeze pipes

Viessmann · Vitotronic 300 GW6B heating circuit pump

A pump switch-off threshold set below 34°F (1°C) can let pipes outside the heated envelope freeze. Consider standby periods such as holidays.

  1. Check the outdoor temperature threshold in coding a3 before leaving the system in standby.
  2. Do not set a3 below 1°C unless the piping is protected.

Heating circuit pump runs periodically in standby

Viessmann · Vitotronic 200-H HK1M

In standby or when the control is off, the heating circuit pump starts for a short time every 24 hours to prevent pump seizure.

Heating circuit selection on HK3S

Viessmann · Vitotronic 200-H HK3S

On the HK3S the heating circuit selection control chooses which circuit is displayed. The basic display can show a first key 1 or 2 or 1, 2 or 3 depending on how many heating circuits are connected.

Heating circuit selection on multi-circuit systems

Viessmann · HK3S (two or three heating circuits)

With two or three heating circuits, the circuit to adjust must be selected before any adjustment or scan. Single-circuit systems skip this step.

  1. Press the circuit key (1, 2 or 3) for the heating circuit to adjust.
  2. Confirm the program keys that light up for that circuit.
  3. Make adjustments or scan only after selecting the circuit.
  4. If no adjustment is made, the key lights go off after a short time.

Heating circuit settings can be made on the control or remote

Viessmann · Vitotronic 200-H HK1S and HK3S

All heating circuit settings can be made on the control unit or the built-in programming unit. If a remote control is fitted, it can be used for the settings as well, following the remote control instructions.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair