Viessmann Air Handler: WORK contact (CN23) for blower status
WORK contact (CN23) for blower status on a Viessmann air handler: Dry normally open output that follows the indoor blower. It is closed while the blower runs and open when it is off. The unit supplies no voltage here, so the external system must provide the power. Rated 250 VAC, 10 A maximum. If you need a 24 V signal, the G and C thermostat terminals can be used instead.
Applies to: Main board CN23 WORK terminal
How to fix work contact (cn23) for blower status: step by step
- Wire the external load to CN23 with its own power source.
- Keep the load within 250 VAC and 10 A.
If the unit shows an error code, look it up: Viessmann Air Handler codes
Models
DLFLABH36XA3DLFLABH48XA3DLFLABH60XA3DLFSABH18XB3DLFSABH24XB3DLFSABH30XB3DLFSABH36XB3DLFUAAQ18XB3DLFUAAQ24XB3DLFUAAQ30XB3DLFUAAQ36XA3DLFUAAQ36XB3DLFUAAQ48XA3DLFUAAQ60XA3
More other tips for air handler
Source: DLFSAB and DLFLAB Service Manual, p. 3. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.