Rheem Furnace: Wire auxiliary switches to T5
Wire auxiliary switches to T5 on a Rheem furnace: Up to two field switches (drain pan, smoke detector, freeze switch and similar) can be wired to the T5 auxiliary inputs on communicating systems only.
Applies to: 96V and 96MDV communicating systems
How to fix wire auxiliary switches to t5: step by step
- Wire each switch to Aux 1 or Aux 2 on terminal T5.
- At the communicating thermostat, set each input as normally open or normally closed.
- Configure what the system does when the contacts open or close at the thermostat.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
More commissioning tips for furnace
Source: 96V installation instructions, p. 98. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.