Rheem Furnace: Thermostat compatibility and wiring
Thermostat compatibility and wiring on a Rheem furnace: Use a thermostat that is not current-robbing. Use 24 volt control wire no smaller than 18 AWG. Run the leads into the blower compartment and connect to the low-voltage terminals shown on the wiring diagram.
Applies to: Thermostat wiring
How to fix thermostat compatibility and wiring: step by step
- Use a thermostat that is not current-robbing.
- Use 24 volt wire of 18 AWG or larger.
- Connect to the low-voltage terminals as shown on the wiring diagram.
- Do not mount the thermostat on an outside wall or where drafts, pipes, ducts, sun or fireplace heat affect it.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
Source: 96V series installation instructions, p. 77. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.