Rheem Furnace: Reset the overtemperature safety switch
Reset the overtemperature safety switch on a Rheem furnace: The overtemperature switches sit in the burner compartment and trip when combustion air is inadequate. A tripped switch must be reset by hand, but only after the cause is cleared.
Applies to: All 96V and 96MDV series furnaces
How to fix reset the overtemperature safety switch: step by step
- Find the cause of the overtemperature trip, usually inadequate combustion air.
- Correct the cause.
- Press the manual reset on the switch in the burner compartment.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
More reset & cancel tips for furnace
Source: 96V series installation instructions, p. 46. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.