Rheem Furnace: Replacing the furnace control (memory card)
Replacing the furnace control (memory card) on a Rheem furnace: The memory card on the original furnace control holds critical model data. It stays with the furnace, tethered by the plastic wire tie, and it moves to the new board. Never use a control from another furnace, because it can contaminate the system with the wrong model data.
Applies to: R96V furnace control
Common causes of replacing the furnace control (memory card)
- Furnace control failed and needs replacing
- Board swap where the card is left behind or lost
- Replacement control with dipswitches set differently from the original
- A spare board pulled from another furnace
How to fix replacing the furnace control (memory card): step by step
- Do not cut the plastic wire tie tethering the memory card
- Remove the memory card from the original furnace control and keep it with the furnace
- Insert the memory card into connector P6 on the replacement control
- Match the dipswitch settings of the original control on the replacement
- Do not use a control board from another furnace
- Power off for the whole swap, and use static precautions on the board
- Power up and confirm the furnace runs a normal cycle with no fault code
If the unit shows an error code, look it up: Rheem Furnace codes
Models
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
Source: Rheem 96V series installation instructions, p. 118. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.