Rheem Furnace: Recommended elbow count
Recommended elbow count on a Rheem furnace: Exceeding the recommended maximum number of elbows can cause nuisance pressure switch operation. Long sweep elbows are preferred. Mixing elbow types is allowed, but standard 90s and 45s used alone at the maximum count may cause nuisance outages.
Applies to: All vent runs
How to fix recommended elbow count: step by step
- Count elbows against the maximum in the Table 4 elbow column for the model.
- Use long sweep 90s wherever possible.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
Source: 96V Series installation instructions, p. 48-49. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.