Rheem Furnace: LP conversion and orifice spud change
LP conversion and orifice spud change on a Rheem furnace: To run this furnace on propane, the gas valve has to be converted by replacing the regulator springs with the kit springs, and the orifice spuds changed as well. Order the correct LP kit from the manufacturer. Conversion must be done by a qualified installer, service agency or gas supplier, because a wrong conversion is a real fire and carbon monoxide hazard. Take care to shut off the gas first, and leak-check every joint when you are done.
Applies to: LP conversion and elevation orifice changes
Common causes of lp conversion and orifice spud change
- Furnace installed on a property with propane instead of natural gas
- Elevation changes that need different orifice spuds
- Swapping fuel after a tank install
- Replacement parts that arrive set for the wrong gas
How to fix lp conversion and orifice spud change: step by step
- Shut off the manual main gas valve and the electrical supply before starting
- Replace the pressure regulator springs with the LP kit springs
- Remove the gas manifold
- Replace the orifice spuds
- Reassemble in reverse order
- Turn gas on and check operation and manifold pressure
- Leak-check all joints with an approved detector
- Attach the notice label stating the furnace has been converted to LP gas
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
Source: 96V series installation instructions, p. 74. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.