Rheem Furnace: Limit total static pressure on the distribution system
Limit total static pressure on the distribution system on a Rheem furnace: Total static pressure drop of the whole air distribution system, including any AC coil, air filtration, zoning, and ductwork, must not exceed 0.8 in W.C. Size the duct for the maximum possible airflow, because heating airflow can be higher than cooling airflow. Check the added equipment data for pressure drop at the recommended heating or cooling CFM.
Applies to: All 96V and 96MDV series furnaces
How to fix limit total static pressure on the distribution system: step by step
- Size duct to the maximum airflow value, not just the cooling value.
- Add up pressure drop of coil, filters, zoning and ductwork.
- Confirm the total is 0.8 in W.C. or less at recommended CFM.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
More commissioning tips for furnace
Source: 96V series installation instructions, p. 42. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.