Rheem Furnace: Legacy 1-stage thermostat jumper
Legacy 1-stage thermostat jumper on a Rheem furnace: A legacy 1-stage thermostat with autostaging is wired to the furnace. For one-stage cooling a jumper is needed between Y1 and Y2.
Applies to: 96V and 96MDV furnaces with legacy thermostats
How to fix legacy 1-stage thermostat jumper: step by step
- Wire the legacy 1-stage thermostat per the autostaging wiring diagram.
- Install a jumper between Y1 and Y2 for one-stage cooling.
- The jumper is only used for heat pump installations in the wiring diagram.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
More commissioning tips for furnace
Source: 96V installation instructions, p. 101. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.