Rheem Furnace: Gas supply piping layout

Updated · by Aurora Star Tech Inc.

Gas supply piping layout on a Rheem furnace: Gas piping has to be sized so the valve gets enough pressure when everything is running, and set up so the valve can be serviced later. Think about the next tech when you build it. A union near the cabinet, a shutoff you can reach and a drip leg all make life easier and keep dirt out of the valve. Everything must follow local codes and the utility's rules, and gas piping is licensed work in most places, so have a qualified gas fitter do it.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Gas supply line and valve connections

Common causes of gas supply piping layout

  • New furnace install needing a gas line run
  • Undersized line that causes low pressure under load
  • No place to remove the gas valve for service
  • Dirt or scale in the line fouling the valve
  • Shared line with other appliances that drops pressure

How to fix gas supply piping layout: step by step

  1. Run a separate gas line from the meter to the furnace where possible
  2. Size the gas line and manual gas stop so pressure drop is not excessive, and never smaller than the pipe size to the gas valve
  3. Use Table 12 for natural gas or Table 13 for LP to select pipe size
  4. Install a ground joint union within 3 ft of the cabinet so the gas valve can be removed
  5. Install a manual shut-off valve outside the furnace casing and upstream of the union, within easy reach
  6. Install a drip leg in the supply line as close to the furnace as possible
  7. Leak-test all joints with an approved method before putting the furnace in service
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rheem Furnace codes

Models

(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100

Source: 96V series installation instructions, p. 70. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.