Rheem Furnace: Gas supply piping arrangement at the furnace
Gas supply piping arrangement at the furnace on a Rheem furnace: Gas supply piping at the Rheem 96V/96MDV, per the gas piping figure. Each branch gets a manual shut-off, a union and a drip leg.
Applies to: Gas piping installation
Common causes of gas supply piping arrangement at the furnace
- Not a fault call. Piping layout requirement. Missing parts here make service difficult and can let dirt reach the gas valve.
How to fix gas supply piping arrangement at the furnace: step by step
- Install a manual shut-off valve ahead of the furnace so gas can be stopped for service.
- Install a union so the furnace can be disconnected without cutting pipe.
- Install a drip leg (sediment trap) in the piping to catch debris before it reaches the gas valve.
- Keep the arrangement horizontal as shown in the figure.
- Leak test every joint after assembly. Gas piping work belongs to a licensed gas fitter.
- Purge and recheck the connection before lighting the furnace.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
Source: 96V series installation instructions, p. 72. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.