Rheem Furnace: Five-minute lockout (low pressure switch fails to close)

Updated · by Aurora Star Tech Inc.

Five-minute lockout (low pressure switch fails to close) on a Rheem furnace: A five-minute soft lockout starts if the low pressure switch does not close within 60 seconds of continuous inducer operation at the start of a heat cycle. The display shows the matching fault. The lockout clears automatically after five minutes, so the furnace may seem to fix itself and then do it again. Be careful when you inspect the vent, because flue gases can contain carbon monoxide. Power off before touching hoses or wiring, and call a licensed technician if the vent or combustion looks wrong.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: R96V furnace

Common causes of five-minute lockout (low pressure switch fails to close)

  • Low pressure switch not closing during the proving period
  • Blocked or restricted venting, including a clogged intake or terminal
  • Loose or faulty wiring
  • Faulty pressure switch or hoses
  • Condensate backing up into the pressure switch hose

How to fix five-minute lockout (low pressure switch fails to close): step by step

  1. Check the vent system for blockage and proper termination
  2. Check the pressure switch hoses for blockage, splits, or disconnection
  3. Look for water in the hose or switch, which means a drain problem
  4. Check the pressure switch and wiring
  5. Wait five minutes for automatic reset, or clear the original fault and cycle power
  6. Watch the next heat cycle and confirm the switch closes within the proving time
  7. If it keeps locking out, have a licensed tech check vent and inducer
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rheem Furnace codes

Models

(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100

Source: Rheem 96V series installation instructions, p. 118. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977