Rheem Furnace: Final review after a horizontal conversion
Final review after a horizontal conversion on a Rheem furnace: Last pass on a Rheem 96V/96MDV horizontal conversion, before you leave the job. Tick every item on the printed checklist. Skip one and you're back for a leak or a vent problem.
Applies to: Horizontal conversions
Common causes of final review after a horizontal conversion
- Not a fault call. Final review list for horizontal conversions.
How to fix final review after a horizontal conversion: step by step
- Verify all hoses are secure and fully seated.
- Confirm all hoses are free of kinks.
- Confirm all hoses and other drain parts slope in the direction of water flow.
- Make sure both worm drives on the flue transition hose clamps sit on the top of the coupling.
- Tighten all clamps and couplings.
- Confirm all drain ports are plugged.
- Confirm the unit has forward pitch.
- Install heat tape if required.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
Source: Rheem 96V installation manual, p. 38. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.