Rheem Furnace: Electronic air cleaner output

Updated · by Aurora Star Tech Inc.

Electronic air cleaner output on a Rheem furnace: Line voltage for an electronic air cleaner comes from the EAC terminal and a neutral terminal on the control board. It runs whenever the circulating blower runs, but only above the minimum target CFM for the model. Maximum current is 1.0 amp.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Furnaces with EAC output

How to fix electronic air cleaner output: step by step

  1. Connect the air cleaner to the EAC terminal and control board neutral.
  2. Confirm the target CFM is above the model threshold, or the output will not energize.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rheem Furnace codes

Models

96V

(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100

96MDV

96MDV06096MDV07096MDV08596MDV100

More other tips for furnace

Source: 96V series installation instructions, p. 78. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.