Rheem Furnace: Electrical supply and overcurrent protection
Electrical supply and overcurrent protection on a Rheem furnace: Match the voltage, frequency and phase to the rating plate. For one furnace, maximum overcurrent protection is 15 amps. Use a separate fused or breaker-protected branch circuit run to a disconnect near the furnace.
Applies to: Furnace electrical supply
How to fix electrical supply and overcurrent protection: step by step
- Confirm voltage, frequency and phase against the rating plate.
- Protect the circuit with a maximum 15 amp fuse or breaker.
- Run the circuit to an accessible disconnect near the furnace.
- Keep electrical components protected from condensate.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
Source: 96V series installation instructions, p. 76. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.