Rheem Furnace: Downflow non-combustible floor base requirement
Downflow non-combustible floor base requirement on a Rheem furnace: A downflow unit is certified only for a non-combustible floor. Use the special base listed on the furnace clearance label. The base is sold as an accessory. Not installing it can cause fire, property damage or injury. A base is needed when installing on a combustible floor without an air conditioning plenum.
Applies to: Downflow installations
How to fix downflow non-combustible floor base requirement: step by step
- Confirm the floor is non-combustible or install the special base from the clearance label.
- Order the base as an accessory if it is not already on site.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
96V
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
96MDV
96MDV06096MDV07096MDV08596MDV100
Source: 96V series installation instructions, p. 43. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.