Rheem Furnace: Condensate trap priming on first start
Condensate trap priming on first start on a Rheem furnace: The condensate trap is self-priming. It starts dry on the first heat attempt after install or after a long off period. Priming can take several cycles, especially on horizontal installs, because there is less water stored in the collector box.
Applies to: Condensate drain trap, all 96V installs
How to fix condensate trap priming on first start: step by step
- Expect the trap to be dry on the first firing after install or after a long summer off period.
- Let the inducer run. Water builds in the collector box until it reaches the lower water level sensor.
- Confirm the trap primes after the heat attempt ends and the inducer shuts off after post purge.
- If the trap is still not primed, allow up to four heat attempts before deciding there is a fault.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
More commissioning tips for furnace
Source: 96V series installation instructions, p. 67. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.