Rheem Furnace: Condensate pump requirements
Condensate pump requirements on a Rheem furnace: The pump must resist acidic water, or a neutralizer must go ahead of it. The pump needs an auxiliary safety switch to stop the furnace if the pump fails.
Applies to: Condensate pump installs
How to fix condensate pump requirements: step by step
- Use an acid-resistant condensate pump, or install a neutralizer ahead of the pump.
- Install an auxiliary safety switch on the pump to prevent furnace operation and overflow if the pump fails.
- Wire the safety switch through the R (low voltage) circuit only so the furnace runs in heating or cooling.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
Source: 96V series installation instructions, p. 67. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.