46.4°F (8°C) heating setback

Carrier · D5FCFA heat pump units

In heating mode the set point can go as low as 46.4°F (8°C) to protect an unoccupied space from freezing.

  1. Set heating mode.
  2. Set the temperature to 46.4°F (8°C).

Activate SILENCE

Carrier · D5FSOA single-zone units

Silence runs the compressor at a lower frequency than F3 and the indoor fan at faint breeze (1%). Not available on Multi-Zone systems and disabled when matched with multi outdoor units.

  1. Press Silence on the remote, or hold FAN for more than 2 seconds.

Air direction louver control

Carrier · Indoor unit louvers

Each SWING press moves the up-down louver 30 degrees. Holding SWING for 2 seconds starts vertical auto swing on some units. Do not move the louver by hand.

  1. Press SWING to step the louver to the next position.
  2. Hold SWING for 2 seconds to start vertical auto swing (some units only).
  3. If the louver has been moved by hand out of range, turn the unit off, then back on.

Airflow from upper or lower outlets

Carrier · Floor console indoor unit, size 12 for lower outlet

The floor console has a dual airflow switch. Single airflow sends air only from the upper outlet, which suits sleeping. The lower outlet is only on size 12.

  1. Open the front panel to reach the airflow selection switch (turn breaker OFF first).
  2. Set the switch to single airflow to send air only from the upper outlet.
  3. Leave it in dual airflow to let the unit choose the blowing pattern automatically.

Auto-restart after power loss

Carrier · Indoor unit

The indoor auto-restart module saves current settings and restores them after a power failure.

  1. Settings are restored automatically within 3 minutes after power returns.
  2. Channel 1 in service mode turns auto-restart on (1) or off (0).

Breeze Away

Carrier · COOL, FAN and DRY modes

Keeps direct airflow off the room occupants. Available in COOL, FAN and DRY modes only.

  1. Press SET, then select Breeze Away and press OK to confirm.

Change indoor unit from 12K to 9K capacity

Carrier · 45MBCAQ12XA3 indoor unit

Downsizing a 45MBCAQ12XA3 indoor unit from 12K to 9K BTU/h using the ENC1 rotary switch. Other capacities stay at factory setting.

  1. Check that ENC1 is at 0 (the 12K default).
  2. Disconnect power first.
  3. Open the electronic control box and set ENC1 to 2. Close the box.
  4. Restore power. The unit now runs as a 9K.

Cycle through ECO and GEAR energy modes

Carrier · Wireless remote control (not available with multi-zone condensers)

The ECO/GEAR button steps through the energy saving options.

  1. Press ECO/GEAR to cycle ECO, GEAR 75%, GEAR 50%.

Cycle through fan speeds

Carrier · Wireless remote control

The FAN button steps through the fan speed options. Fan speed can also be fine-tuned with TEMP.

  1. Press FAN to cycle AUTO, 20%, 40%, 60%, 80%, 100%.
  2. Press TEMP up or down to change fan speed in 1% steps.

Cycle through operating modes

Carrier · Wireless remote control

The MODE button steps through the operating modes in a fixed order.

  1. Press MODE to step through AUTO, COOL, DRY, HEAT and FAN.
  2. HEAT is only available on heat pump models.

Cycle through remote feature functions

Carrier · Wireless remote control

The SET button scrolls through extra operating features, and OK confirms the selected one.

  1. Press SET to scroll through Breeze Away, Clean, Fresh, Sleep, Follow Me, AP mode and Breeze Active.
  2. Press OK to confirm the flashing symbol.

Dry mode humidity adjustment

Carrier · D5FCFAH wireless remote controller

In DRY mode the room humidity can be set from 35% to 85% in 5% steps. The humidity sensor is not active on floor consoles matched with multi-zone outdoor units or when a wired controller is used.

  1. Select DRY mode.
  2. Press the HUMIDITY button to set the target in 5% steps between 35% and 85%.

ECO and GEAR energy-saving modes

Carrier · Wireless remote controller, cooling mode

ECO is only available in COOLING mode. It holds the temperature between 75°F and 86°F with AUTO fan and lasts 8 hours. GEAR steps down to 75% and 50% of electrical consumption.

  1. In COOLING mode, press ECO/GEAR to start ECO.
  2. Press ECO/GEAR again to cycle to GEAR 75% and then GEAR 50%.
  3. Keep cycling to return to the previous setting before ECO.

ECO energy mode

Carrier · Single-zone D5FCFAH systems

Press ECO to enter energy efficient mode. In COOLING, the unit adjusts the set point to 75 F (24 C) and uses AUTO fan when the set point is below 75 F. ECO ends after 8 hours, or when ECO is pressed again, the mode is changed, or the set point is lowered below 75 F.

  1. Press ECO to enter the mode.
  2. Press ECO again, change mode, or set below 75 F (24 C) to exit early.

ECO energy saving mode

Carrier · D5FCFA single-zone units

In cooling, ECO sets the temperature to 75°F / 24°C and fan to auto, only if the set point is below 75°F. ECO runs for 8 hours.

  1. In cooling mode, press ECO on the remote.
  2. Press ECO again, change mode, or set the temperature below 75°F / 24°C to leave ECO.

ECO function (not on multi-zone systems)

Carrier · D5FCFAH

In cooling, ECO sets the remote to 75°F (24°C) with Auto fan if the setpoint is below 75°F. If the setpoint is between 75°F and 86°F, only the fan changes to Auto. ECO ends when ECO is pressed again, the mode changes, the setpoint is moved below 75°F, or after 8 hours.

  1. Press ECO in cooling to start.
  2. Press ECO again, change mode, or lower the setpoint below 75°F to exit early.

Energy consumption control (Gear button)

Carrier · D5FSOA single-zone units

Gear button cycles the remote through the energy efficient mode sequence. Turning the unit off or activating ECO, SLEEP, Super Cool, 8°C heating, Silence or self clean cancels it.

  1. Press the Gear button on the remote to enter the energy efficient sequence.

Enter Silence mode from the remote

Carrier · D5FCFA single-zone units

Silence mode lowers the compressor frequency and runs the indoor fan at faint breeze. It is not available on multi-zone systems or with a multi outdoor unit.

  1. Press Silence on the remote control.
  2. Or hold FAN for more than 2 seconds on the remote control.

Fan speed limits by mode

Carrier · Wireless remote RG10F8(2)/BGEFU1

Fan speed can be set in COOL, HEAT and FAN modes. It cannot be adjusted in AUTO or DRY mode, where the unit sets it automatically.

  1. Press FAN to select the fan speed in COOL or HEAT.
  2. Set FAN mode speed with the FAN button.

Fan speed selection order

Carrier · Wireless remote controller, all modes

The fan speed cycles AUTO, 20%, 40%, 60%, 80%, 100%. Fan speed cannot be set in AUTO or DRY mode. TEMP up or down changes fan speed in 1% steps.

  1. Press FAN to step through AUTO, 20%, 40%, 60%, 80% and 100%.
  2. To fine-tune, press TEMP up or down to change fan speed in 1% steps.
  3. In AUTO or DRY mode, expect the fan speed to be set automatically.

Follow Me function

Carrier · D5FCFAH wireless remote controller

When Follow Me is active, the remote sends its temperature signal every 3 minutes with no beeps. The function turns off if no signal is received for 7 minutes or if Follow Me is pressed again. The unit does not change mode from its own temperature setting.

  1. Press FOLLOW ME to activate or deactivate.

Remote control feature availability

Carrier · Wireless remote RG10F8(2)/BGEFU1

Intelligence Sensor and Vertical Swing are not available on this unit. Several functions such as Humidity Control, ECO, Active Clean, Gear and Silent Mode are not available when matched with multi-zone condensers. Some indicators on the remote are marked not applicable for this unit.

Remote control setpoint and fan ranges

Carrier · Wireless remote RG10L5(2HS)

Temperature and humidity limits and the fan speed sequence on the remote.

  1. Temperature setpoint range is 16°C (60°F) to 30°C (86°F), changed in 0.5°C (1°F) steps.
  2. Dehumidification humidity range is 35% to 85%, changed in 5% steps.
  3. Fan speed order: AUTO, then 20%, 40%, 60%, 80%, 100%. Fan speed can be adjusted in 1% steps with the TEMP buttons.

SILENCE mode and LED light

Carrier · D5FSFAH floor console ductless system

SILENCE lowers indoor fan to faint breeze (1% fan speed). LED toggles the display light.

  1. Press SILENCE on the remote to turn the function on.
  2. Press LED to turn the display light on or off.

SLEEP mode

Carrier · D5FSFAH floor console ductless system

Energy-saving mode for COOL, HEAT or AUTO. Works with the remote control only.

  1. Press SLEEP.
  2. In COOLING, the set point rises 1.8 F (1 C) after 1 hour, rises another 1.8 F after a second hour, and the fan runs low; unit shuts off 5 hours after setting.
  3. In HEATING, set points are lowered by 1.8 F (1 C).
  4. SLEEP cancels if MODE, TEMP, FAN, TIMER or ON/OFF is pressed.

Switch remote between F and C

Carrier · Wireless remote controller

The remote defaults to Fahrenheit. To change the display to Celsius, press and hold the + and - temperature buttons together for about 3 seconds.

  1. Point the remote at the unit.
  2. Press and hold the + and - set point buttons together for about 3 seconds.

Temperature set point limits on remote

Carrier · Wireless remote RG10F8(2)/BGEFU1

The set point range depends on model: 60-86 F (16-30 C) or 68-82 F (20-28 C). The unit accepts set points from 62 F (17 C) to 86 F (30 C) in 1 F or 1 C steps. Temperature can be raised or lowered in 1 F (0.5 C) steps.

Timer function

Carrier · D5FCFAH

24-hour timing range. Timer modes: TIMER ON, TIMER OFF, TIMER ON/OFF and TIMER OFF/ON. The timer does not change the current operation mode. Setting TIMER OFF on an off unit will not start it. Times are relative and the timer exits if a malfunction occurs.

  1. Select the timer mode on the remote.
  2. Set the on and/or off times within the 24-hour range.

Timer ON and TIMER OFF

Carrier · D5FSFAH floor console ductless system

Timer ON starts the unit at a set time; TIMER OFF stops it. Both can be used separately or together.

  1. Press TIMER ON to set the start time; each press adds 30 minutes up to 10 h, then 60 minutes up to 24 h.
  2. Press TIMER OFF to set the stop time with the same increments.
  3. Set the timer to 0.0 to cancel it.
  4. To program both, set TIMER ON and TIMER OFF in the order described in the manual for the unit's current state.

TURBO mode

Carrier · D5FSFAH floor console ductless system

Rapid cooling or heating; fan runs on super high speed.

  1. Press TURBO; a beep sounds if the indoor unit supports it.
  2. TURBO ends automatically after 20 minutes.
  3. To cancel early, press TURBO again; the unit returns to its previous setting.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.