Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Air Conditioner: Waste (sewer) line connection with air gap trap

Updated · by Aurora Star Tech Inc.

Waste (sewer) line connection with air gap trap on a Carrier air conditioner: When the condensate line goes to a waste or sewer line, an open trap must be installed ahead of the waste line to keep sewer gases out. The drain line needs an air gap at the trap. Failure to do this can cause personal injury or death.

Homeowner with a air conditioner problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DLFULA condensate drain to sewer (Fig. 16 Air Gap)

How to fix waste (sewer) line connection with air gap trap: step by step

  1. Install an open trap ahead of the waste (sewer) line.
  2. Provide a 3 in (76 mm) air gap above the liquid level at the trap.
  3. Confirm the air gap is present in the drain line before connecting to the sewer line.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Air Conditioner codes

More commissioning tips for air conditioner

Source: DLFULA Installation Instructions, p. 16. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977