Trane Error Code Flashing flame icon: Second-stage heat energized (Heat Pump)
Trane error code Flashing flame icon on a heat pump means: Second-stage heat energized. It is also called Trane diagnostic code Flashing flame icon.
Homeowner? What Trane code Flashing flame icon means for you
Usually minor Your heat pump is reporting: Second-stage heat energized. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Trane error code Flashing flame icon mean?
Flame icon flashes when 2nd-stage heat (auxiliary or emergency) is on.
Applies to: XR103 thermostat
Other Trane Heat Pump codes
All Trane Heat Pump error codes →
Trane code Flashing flame icon: homeowner questions
What does Trane code Flashing flame icon mean?
Second-stage heat energized. Flame icon flashes when 2nd-stage heat (auxiliary or emergency) is on.
Is it safe to keep using my heat pump with code Flashing flame icon?
Usually yes. Code Flashing flame icon is normally minor, but if it keeps coming back have it checked.
Can I reset Trane code Flashing flame icon myself?
You can try one reset (power off for 30 seconds, then on). If Trane code Flashing flame icon comes back, the cause is still there and a licensed technician should check it.
Who can fix Trane code Flashing flame icon near me?
Aurora Star Tech Inc. repairs Trane heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Trane XR103 installation and user guide 18-HD55D1-1C-EN, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.