NTI Error Code Lockout 215: Invalid Purge rate proving setting (Boiler)

Updated · by Aurora Star Tech Inc.

NTI error code Lockout 215 on a boiler means: Invalid Purge rate proving setting. It is also called NTI diagnostic code Lockout 215.

High severityBoilerAlso BoilerTrinity Tft

Homeowner? What NTI code Lockout 215 means for you

Call a technician Your boiler is reporting: Invalid Purge rate proving setting. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does NTI error code Lockout 215 mean?

The control rejected a configuration value: invalid Purge rate proving setting.

Applies to: Trinity Tft60, Tft85, Tft110, Tft155, Tft175, Tft200, Tft250, Tft300, Tft399

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

NTI models that use code Lockout 215

Tft60Tft60Tft85Tft85Tft110Tft110Tft154Tft155Tft175Tft200Tft201Tft250Tft285Tft300Tft340Tft399Tft399

Other NTI Boiler codes

CodeMeaning
Lockout 212Invalid Pre-ignition time setting
Lockout 212Invalid Pre-ignition time setting
Lockout 213Invalid Pre-purge rate setting
Lockout 213Invalid Pre-purge rate setting
Lockout 214Invalid Pre-purge time setting
Lockout 214Invalid Pre-purge time setting
Lockout 215Invalid Purge rate proving setting
Lockout 216Invalid Run flame failure response setting
Lockout 216Invalid Run flame failure response setting
Lockout 217Invalid Run stabilization time setting
Lockout 217Invalid Run stabilization time setting
Lockout 218Invalid Stack limit enable setting

All NTI Boiler error codes →

NTI code Lockout 215: homeowner questions

What does NTI code Lockout 215 mean?

Invalid Purge rate proving setting. The control rejected a configuration value: invalid Purge rate proving setting.

Is it safe to keep using my boiler with code Lockout 215?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset NTI code Lockout 215 myself?

You can try one reset (power off for 30 seconds, then on). If NTI code Lockout 215 comes back, the cause is still there and a licensed technician should check it.

Who can fix NTI code Lockout 215 near me?

Aurora Star Tech Inc. repairs NTI boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: NTI Tft60-399 Installation and Operation Instructions (rev. 2012-04-09), Sec. 15.0 Troubleshooting, Table 15-3. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.