NTI Error Code Alert 174: DHW outlet temperature was invalid (Boiler)

Updated · by Aurora Star Tech Inc.

NTI error code Alert 174 on a boiler means: DHW outlet temperature was invalid. It is also called NTI diagnostic code Alert 174.

Low severityBoilerTrinity Tft

Homeowner? What NTI code Alert 174 means for you

Usually minor Your boiler is reporting: DHW outlet temperature was invalid. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does NTI error code Alert 174 mean?

DHW outlet temperature was invalid.

Applies to: Trinity Tft60, Tft85, Tft110, Tft154, Tft201, Tft285, Tft340, Tft399

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

NTI models that use code Alert 174

Tft60Tft60Tft85Tft85Tft110Tft110Tft154Tft155Tft175Tft200Tft201Tft250Tft285Tft300Tft340Tft399Tft399

Other NTI Boiler codes

CodeMeaning
Alert 171DHW control was suspended due to fault
Alert 172DHW temperature was invalid
Alert 172DHW temperature was invalid
Alert 173DHW inlet temperature was invalid
Alert 173DHW inlet temperature was invalid
Alert 174DHW outlet temperature was invalid
Alert 175DHW high limit must be disabled for Auto mode
Alert 176DHW sensor type was not compatible for Auto mode
Alert 177DHW priority source setting was invalid
Alert 178DHW priority method setting was invalid
Alert 179CH S5 (J8-11) sensor was invalid
Alert 180CH Inlet temperature was invalid

All NTI Boiler error codes →

NTI code Alert 174: homeowner questions

What does NTI code Alert 174 mean?

DHW outlet temperature was invalid. DHW outlet temperature was invalid.

Is it safe to keep using my boiler with code Alert 174?

Usually yes. Code Alert 174 is normally minor, but if it keeps coming back have it checked.

Can I reset NTI code Alert 174 myself?

You can try one reset (power off for 30 seconds, then on). If NTI code Alert 174 comes back, the cause is still there and a licensed technician should check it.

Who can fix NTI code Alert 174 near me?

Aurora Star Tech Inc. repairs NTI boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: NTI Trinity Tft399 Installation and Operation Manual (2018-09-07), Sec. 16.0 Troubleshooting, Table 16-4. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.