Mitsubishi Error Code E6: Indoor/outdoor communication – indoor not receiving (Heat Pump)

Updated · by Aurora Star Tech Inc.

Mitsubishi error code E6 on a heat pump means: Indoor/outdoor communication - indoor not receiving. It is also called Mitsubishi diagnostic code E6.

High severityHeat PumpMr. Slim PEAD-RP JA(L) ducted indoor unit

Homeowner? What Mitsubishi code E6 means for you

Call a technician Your heat pump is reporting: Indoor/outdoor communication - indoor not receiving. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Mitsubishi error code E6 mean?

The indoor board has not received a valid signal from the outdoor unit for 6 minutes after power-up, or for 3 minutes during operation. On twin/triple systems, also set when the indoor board does not get the outdoor board's permission-to-send signal for 3 minutes.

Applies to: PEAD-RP35/50/60/71/100/125/140JA and JA(L) ducted indoor units (220-240 V models)

Common causes of Mitsubishi code E6

  • S1/S2/S3 indoor-outdoor wire loose, shorted or crossed
  • Faulty send/receive circuit on the indoor board
  • Faulty send/receive circuit on the outdoor board

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Mitsubishi models that use code E6

PEAD-RP35JAPEAD-RP35JALPEAD-RP50JAPEAD-RP50JALPEAD-RP60JAPEAD-RP60JALPEAD-RP71JAPEAD-RP71JALPEAD-RP100JAPEAD-RP100JALPEAD-RP125JAPEAD-RP125JALPEAD-RP140JAPEAD-RP140JAL

Other Mitsubishi Heat Pump codes

CodeMeaning
E0Remote controller not receiving from indoor unit
E1Remote controller memory error
E2Remote controller clock error
E3Remote controller cannot transmit
E4Indoor unit not receiving from remote controller
E5Indoor unit cannot transmit to remote controller
E7Indoor unit transmit error to outdoor unit
FbIndoor control board memory error
FILTERClean the filter indicator
LED1 (indoor board)Indoor board LED1 - control power
LED2 (indoor board)Indoor board LED2 - remote controller power
LED3 (indoor board)Indoor board LED3 - indoor/outdoor communication

All Mitsubishi Heat Pump error codes →

Mitsubishi code E6: homeowner questions

What does Mitsubishi code E6 mean?

Indoor/outdoor communication - indoor not receiving. The indoor board has not received a valid signal from the outdoor unit for 6 minutes after power-up, or for 3 minutes during operation. On twin/triple systems, also set when the indoor board does not get the outdoor board's…

Is it safe to keep using my heat pump with code E6?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Mitsubishi code E6 myself?

You can try one reset (power off for 30 seconds, then on). If Mitsubishi code E6 comes back, the cause is still there and a licensed technician should check it.

Who can fix Mitsubishi code E6 near me?

Aurora Star Tech Inc. repairs Mitsubishi heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Mitsubishi Electric PEAD-RP35-140JA(L) Service Manual, 10-3 Self-diagnosis action table, p.34. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.