Mitsubishi Error Code E2: Remote controller clock error (Heat Pump)
Mitsubishi error code E2 on a heat pump means: Remote controller clock error. It is also called Mitsubishi diagnostic code E2.
Homeowner? What Mitsubishi code E2 means for you
Usually minor Your heat pump is reporting: Remote controller clock error. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Mitsubishi error code E2 mean?
The remote controller's clock function is not working.
Applies to: PEAD-RP35/50/60/71/100/125/140JA and JA(L) ducted indoor units (220-240 V models)
Common causes of Mitsubishi code E2
- Faulty remote controller
Mitsubishi models that use code E2
PEAD-RP35JAPEAD-RP35JALPEAD-RP50JAPEAD-RP50JALPEAD-RP60JAPEAD-RP60JALPEAD-RP71JAPEAD-RP71JALPEAD-RP100JAPEAD-RP100JALPEAD-RP125JAPEAD-RP125JALPEAD-RP140JAPEAD-RP140JAL
Other Mitsubishi Heat Pump codes
All Mitsubishi Heat Pump error codes →
Mitsubishi code E2: homeowner questions
What does Mitsubishi code E2 mean?
Remote controller clock error. The remote controller's clock function is not working.
Is it safe to keep using my heat pump with code E2?
Usually yes. Code E2 is normally minor, but if it keeps coming back have it checked.
Can I reset Mitsubishi code E2 myself?
You can try one reset (power off for 30 seconds, then on). If Mitsubishi code E2 comes back, the cause is still there and a licensed technician should check it.
Who can fix Mitsubishi code E2 near me?
Aurora Star Tech Inc. repairs Mitsubishi heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Mitsubishi Electric PEAD-RP35-140JA(L) Service Manual, 10-3 Self-diagnosis action table, p.34. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.