Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Midea Error Code EC57: refrigerant pipe temperature sensor fault (Heat Pump)

Updated · by Aurora Star Tech Inc.

Midea error code EC57 on a heat pump means: refrigerant pipe temperature sensor fault. It is also called Midea diagnostic code EC57.

Medium severityHeat PumpMidea DLCURA ducted single-zone inverter heat pump (outdoor)

Homeowner? What Midea code EC57 means for you

Check, then call Your heat pump is reporting: refrigerant pipe temperature sensor fault. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Midea error code EC57 mean?

The outdoor board reads the refrigerant pipe temperature sensor as open or shorted. Manual gives the meaning only; steps are standard sensor checks.

Applies to: DLCURAH18-60 AAK/ABK single-zone heat pump outdoor units (18K-60K, regular and High Heat)

Common causes of Midea code EC57

  • Sensor connector loose or unplugged on outdoor board
  • Damaged sensor wire
  • Failed sensor

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Midea models that use code EC57

DLCURAH18AAKDLCURAH18ABKDLCURAH24AAKDLCURAH24ABKDLCURAH30AAKDLCURAH30ABKDLCURAH36AAKDLCURAH36ABKDLCURAH48AAKDLCURAH48ABKDLCURAH60AAKDLCURAH60ABK

Other Midea Heat Pump codes

CodeMeaning
EC5CHigh pressure sensor failure
EC50outdoor temperature sensor fault
EC51Outdoor EEPROM error
EC52condenser coil temperature sensor fault
EC53outdoor ambient temperature sensor fault
EC54Discharge temperature sensor (TP) open/short
EC71Outdoor DC fan motor over-current
EC72Outdoor DC fan motor lack-phase
EL01Indoor/outdoor communication error
EL16Main board to transit board communication error
LC06Inverter module (IPM) high temperature protection
PC0ACondenser high temperature protection

All Midea Heat Pump error codes →

Midea code EC57: homeowner questions

What does Midea code EC57 mean?

refrigerant pipe temperature sensor fault. The outdoor board reads the refrigerant pipe temperature sensor as open or shorted. Manual gives the meaning only; steps are standard sensor checks.

Is it safe to keep using my heat pump with code EC57?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Midea code EC57 myself?

You can try one reset (power off for 30 seconds, then on). If Midea code EC57 comes back, the cause is still there and a licensed technician should check it.

Who can fix Midea code EC57 near me?

Aurora Star Tech Inc. repairs Midea heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Source: Midea/Carrier DLCURA Installation Instructions (Catalog DLCURA-03SI), Table 11 Outdoor Unit Diagnostic Codes, p.19. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.